A 100 m-long, 66 kV, 3-core high temperature superconducting power cable system prototype has been developed and installed in order to verify its properties and performance for practical use. The cable is a cold dielectric type with three cable-cores placed in co-axial stainless corrugated pipes. After cooling the cable to LN2 temperature, long duration tests, such as that for nominal current-voltage loading and that for load fluctuation, were performed for a one-year period. The cable was warmed to room temperature after each test to investigate the influence of the heat cycle. Critical current was more than 2.7 kA at 77.3 K, and AC loss was 0.7 W/m/phase at 1 kArms. The magnitude of shielding current was almost equal to the transport current. Capacitance, dielectric losses and other electric properties were also measured. All values showed no change during the tests, and were in good agreement with calculated expectations.
机译:已经开发并安装了100 m长,66 kV,3芯高温超导电力电缆系统原型,以验证其性能和实际使用性能。电缆是冷电介质类型,在同轴的不锈钢波纹管中放置了三个电缆芯。将电缆冷却到LN2温度后,进行了为期一年的长时间测试,例如额定电流-电压负载和负载波动的测试。每次测试后,将电缆加热到室温,以研究热循环的影响。临界电流在77.3 K时大于2.7 kA,在1 kArms时AC损耗为0.7 W / m /相。屏蔽电流的大小几乎等于传输电流。还测量了电容,介电损耗和其他电性能。测试期间所有值均未显示变化,并且与计算出的期望值非常一致。