首页> 外文期刊>IEEE Transactions on Applied Superconductivity >AC loss properties of a 4 kJ conduction-cooled pulse coil wound with a Bi2223 6-strand parallel conductor for SMES
【24h】

AC loss properties of a 4 kJ conduction-cooled pulse coil wound with a Bi2223 6-strand parallel conductor for SMES

机译:SMES用Bi2223 6股并联导体缠绕的4 kJ传导冷却脉冲线圈的交流损耗特性

获取原文
获取原文并翻译 | 示例

摘要

We designed and fabricated a 4 kJ conduction-cooled superconducting pulse coil with a 6-strand interlayer-transposed parallel conductor composed of Bi2223 multifilamentary tapes. We adopted the helium gas forced-flow cooling system where the helium gas flowed inside a copper pipe soldered with the flanges of brass. We succeeded in the continuous pulse operation with an amplitude of 500 A-1.6 T at a sweep rate of 140 A/s at 30 K as designed. Even in the ac operation with an ac loss of 120 W, the difference in temperature inside the winding was only 5 K and it was possible to hold the coil temperature around 30 K. In this paper, we report the design and the test results of the coil system from the aspect of ac loss and thermal properties.
机译:我们设计和制造了一个4 kJ传导冷却超导脉冲线圈,该线圈具有由Bi2223复丝带构成的6股夹层插入的平行导体。我们采用了氦气强制流冷却系统,其中氦气在焊接有黄铜法兰的铜管内流动。按照设计,我们成功地以140 A / s的扫描速率在500 K-1.6 T的振幅下以500 A-1.6 T的幅度连续进行了脉冲操作。即使在交流损耗为120 W的交流运行中,绕组内部的温度差也仅为5 K,并且可以将线圈温度保持在30 K左右。在本文中,我们报告了该设计和测试结果从交流损耗和热性能的角度来看线圈系统。