In the frame of the W7-X stellarator project, CEA cooperates with Max-Planck-Institut fur Plasmaphysik to perform the acceptance tests of all 70 superconducting coils of the W7-X magnet system. The test facility is now complete and its performance is being checked using the W7-X prototype coil. The main objective of the tests of the series coils is to demonstrate their proper function and to determine their margin of operation. Since many coils will be tested and compared to each other, it is important to measure the margin of operation in a reproducible way with sufficient accuracy. Either increasing the current, increasing the temperature or mixed operation can induce quenches. The test results on the prototype coil are analyzed with respect to the temperature and current margin and compared to the expected values calculated from superconducting strand data. The paper summarizes the results of these tests and the methods of evaluation.
机译:在W7-X恒星器项目的框架内,CEA与Max-Planck-Institut Fur Plasmaphysik合作,对W7-X磁体系统的所有70个超导线圈进行了验收测试。现在,测试设备已经完成,并且正在使用W7-X原型线圈检查其性能。串联线圈测试的主要目的是证明其正常功能并确定其工作裕度。由于将对许多线圈进行测试并进行比较,因此以可重复的方式以足够的精度测量操作裕度非常重要。增加电流,增加温度或混合操作都可能引起失超。针对温度和电流裕度分析原型线圈上的测试结果,并将其与根据超导股线数据计算出的预期值进行比较。本文总结了这些测试的结果和评估方法。