首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Reduction of steady-state impedance in magnetic shielding type superconducting fault current limiter
【24h】

Reduction of steady-state impedance in magnetic shielding type superconducting fault current limiter

机译:降低磁屏蔽型超导故障限流器的稳态阻抗

获取原文
获取原文并翻译 | 示例

摘要

A magnetic shielding type superconducting fault current limiter (MSFCL) has undesirable leakage impedance and thus the voltage drop relating to the leakage impedance occurs in the steady-state operation (the standby condition of a fault). Therefore, in this paper, a divided MSFCL model is proposed to reduce the value of the leakage impedance in the steady-state operation. The divided model of MSFCL was actually constructed. Then, some experiments were carried out to demonstrate the advantage of the divided model. We confirmed the advantage of the divided model of the MSFCL through these experiments.
机译:磁屏蔽型超导故障电流限制器(MSFCL)具有不希望的泄漏阻抗,因此在稳态操作(故障的待机状态)下会发生与泄漏阻抗有关的电压降。因此,本文提出了一种划分MSFCL模型,以减小稳态工作时的泄漏阻抗值。实际构造了MSFCL的划分模型。然后,进行了一些实验以证明分割模型的优点。通过这些实验,我们证实了MSFCL划分模型的优势。