首页> 外文期刊>IEEE Transactions on Applied Superconductivity >The DC performance of the so-called good joint Nb3Sn short sample conductor, measured in the SULTAN facility in 1999 with a progressively reduced (chopped) joint length, became worse as the joint became shorter. In this paper we present the an
【24h】

The DC performance of the so-called good joint Nb3Sn short sample conductor, measured in the SULTAN facility in 1999 with a progressively reduced (chopped) joint length, became worse as the joint became shorter. In this paper we present the an

机译:1999年在SULTAN设施中测量的所谓的优质Nb3Sn短接头优良导体的直流性能随着接头长度的缩短而逐渐减小(被切短)。在本文中,我们介绍了

获取原文
获取原文并翻译 | 示例

摘要

The DC performance of the so-called good joint Nb3Sn short sample conductor, measured in the SULTAN facility in 1999 with a progressively reduced (chopped) joint length, became worse as the joint became shorter. In this paper we present the analysis of those tests using the THELMA code. The results confirm quantitatively that the loss of performance was due to increasingly unbalanced current distribution. Once the unbalance due to the joint is properly modeled, the performance of the conductor can be fitted using the same extra longitudinal strain in the critical current scaling, proportional to the electromagnetic load but independent of the joint length.
机译:1999年在SULTAN设施中测量的所谓的优质Nb3Sn短接头优良导体的直流性能随着接头长度的缩短而逐渐减小(被切短)。在本文中,我们使用THELMA代码对这些测试进行了分析。结果定量地证实了性能损失是由于越来越不平衡的电流分配所致。一旦正确地模拟了由于接头引起的不平衡,就可以在临界电流比例中使用相同的额外纵向应变来拟合导体的性能,该纵向应变与电磁负载成比例,但与接头长度无关。