首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Current-Lead Design for Cryocooled HTS Fault Current Limiters
【24h】

Current-Lead Design for Cryocooled HTS Fault Current Limiters

机译:低温HTS故障限流器的电流引线设计

获取原文
获取原文并翻译 | 示例

摘要

A comprehensive design procedure is presented for the current leads in HTS fault current limiters continuously refrigerated by a cryocooler. Two specific aspects are focused here in addition to the standard lead-design. The first is an optimization with taking into account the heat conduction through electrical insulator needed for high-voltage applications. Through a rigorous analysis, it is verified that the standard design should be modified in order to minimize the overall heat leak. The second is the transient thermal behavior that may be caused by excessive current. A numerical analysis is performed to estimate the peak temperature after a short current-limiting period, including the effect of fins as enhanced local heat capacity. Some of the design details are demonstrated for the specifications of FCL''''s under development in Korean Ru00026;D Programs.
机译:针对低温冷却器连续制冷的HTS故障限流器中的电流引线,提出了一种全面的设计程序。除标准引线设计外,此处还重点关注两个特定方面。首先是优化,要考虑到高压应用所需的通过绝缘子的热传导。通过严格的分析,验证了应修改标准设计,以最大程度地减少总体热泄漏。第二个是瞬态热行为,它可能是由于电流过大引起的。进行了数值分析,以估算短时限流后的峰值温度,其中包括散热片作为增强的局部热容的影响。韩国Ru00026; D程序正在开发中的FCL规格说明了一些设计细节。