This paper presents the design and performance results of a pair of conduction-cooled brass current leads for a resistive superconducting fault current limiter (SFCL) system. The 24 kV class SFCL, which has been recently developed by the KEPRI-LSIS collaboration group in Korea, requires three pairs of conduction-cooled brass current leads operated continuously at 630 A. When the SFCL system is in the fault-mode, the current leads have experienced a 60-Hz fault current of $sim$10 kA at 24 kV for 3–5 cycles. In this paper, we present the performance results of the conduction-cooled brass (commercial brass, 10% Zn) leads having a rated current of 667 A operated in a bath of liquid nitrogen.
机译:本文介绍了用于电阻超导故障限流器(SFCL)系统的一对传导冷却黄铜电流引线的设计和性能结果。韩国KEPRI-LSIS合作小组最近开发的24 kV级SFCL需要三对以630 A电流连续运行的传导冷却黄铜电流引线。当SFCL系统处于故障模式时,电流引线在24 kV下经历了3–5个周期的60 Hz故障电流$ sim $ 10 kA。在本文中,我们介绍了在液氮浴中操作的,额定电流为667 A的传导冷却黄铜(商业黄铜,含Zn 10%)引线的性能结果。