Helical coils of the Large Helical Device (LHD) are large scale superconducting magnets for fusion plasma experiments. The cooling system was upgraded in 2006 to improve the cryogenic stability of the coils by subcooling supplied helium. After the upgrade, the subcooled helium of designed mass flow rate of 50 g/s at designed temperature of 3.2 K has been supplied to the coils stably during steady state subcooling operations. The supplied helium is subcooled at a heat exchanger in a saturated helium bath. A series of two centrifugal cold compressors are utilized in the subcooling system to reduce the bath pressure and temperature. It is necessary to operate the cold compressors within a range of appropriate mass flow rate in order to escape from surge and choke.
机译:大型螺旋装置(LHD)的螺旋线圈是用于聚变等离子体实验的大型超导磁体。 2006年对冷却系统进行了升级,以通过对氦气进行过冷来提高盘管的低温稳定性。升级后,在稳态过冷操作期间,已稳定地将设计质量流量为50 g / s,设计温度为3.2 K的过冷氦稳定地供应到盘管。所供应的氦气在热交换器中的饱和氦浴中过冷。过冷系统中使用了一系列的两个离心式冷压缩机,以降低熔池压力和温度。为了避免喘振和节流,必须在适当的质量流量范围内运行冷压缩机。