The preliminary design of the heat exchanger part for the pair of 30 kA hybrid current leads that will be installed in the ENEA 12 T CICC facility is presented. To limit the overall length and the amount of cooling gas to be employed, a hybrid resistive/HTS configuration has been conceived. Regarding the resistive part, a screw-like solution has been adopted for the following reasons: first to guarantee that helium would wet all the finned surfaces of the heat exchanger limiting possible short-path typically present in braided solutions, then to guarantee a proper insulation by creating a counter screw that seals this component and finally to limit the manufacture cost. Starting from the conceptual design were the hybrid model has been studied, in the present paper the resistive section is analysed in greater detail making use of a dedicated 1-D convective tool and 3-D finite element analyses.
机译:介绍了将用于ENEA 12 T CICC设施中的一对30 kA混合电流导线的热交换器部分的初步设计。为了限制要使用的总长度和冷却气体的量,已经构想了混合电阻/ HTS配置。对于电阻部分,由于以下原因而采用了螺钉状的解决方案:首先确保氦气会润湿热交换器的所有翅片表面,从而限制编织溶液中通常存在的可能的短程,然后确保适当的绝缘通过创建密封该组件的沉头螺钉并最终限制制造成本。从概念设计开始,研究了混合模型,在本文中,通过专用的一维对流工具和3-D有限元分析,对电阻部分进行了更详细的分析。