首页> 外文期刊>Applied Superconductivity, IEEE Transactions on >Transverse Stress Effects on Critical Current and Joint Resistance in Mechanical Lap Joint of a Stacked HTS Conductor
【24h】

Transverse Stress Effects on Critical Current and Joint Resistance in Mechanical Lap Joint of a Stacked HTS Conductor

机译:横向应力对叠层HTS导体机械搭接接头中的临界电流和接头电阻的影响

获取原文
获取原文并翻译 | 示例
           

摘要

This paper discussed feasibility of bridge-type and multi-layer mechanical lap joint of a stacked HTS conductor. In the multi-layer mechanical lap joint, a decrease in critical current induced by transverse compressive joint force is one of the important factor to decide joint resistance. In addition, misalignment of joint section could be a problem because respective HTS tapes consisting the stacked HTS conductor could have slightly different thickness. In this study, therefore, transverse stress effect on critical current of stacked BSCCO and GdBCO conductors was experimentally investigated at first. Then, bridge-type mechanical lap joints of single layer and 2-layer HTS conductors were tested to confirm their performance and to consider the misalignment of joint section. Experimental results showed that critical current of the BSCCO conductor decreased at lower stress when the number of layers increased whereas that of the GdBCO conductor was less influenced by the stress. Joint resistance in the bridge-type mechanical lap joint was comparable to those in normal mechanical lap joint and soldered lap joint in the case of the single layer. Joint resistances in the 2-layer lap joint were two or three times larger than those in the single layer lap joint due to the misalignment. To solve this problem, compliant metal layer should be inserted into joint section.
机译:本文讨论了叠层高温超导导体桥式多层机械搭接的可行性。在多层机械搭接接头中,由横向压缩接头力引起的临界电流的减小是决定接头电阻的重要因素之一。另外,由于构成堆叠的HTS导体的各个HTS带可能具有略微不同的厚度,所以接合部的未对准可能是个问题。因此,在本研究中,首先通过实验研究了横向应力对堆叠的BSCCO和GdBCO导体的临界电流的影响。然后,测试了单层和两层HTS导体的桥式机械搭接接头,以确认其性能并考虑接头截面的未对准情况。实验结果表明,当层数增加时,BSCCO导体的临界电流在较低的应力下减小,而GdBCO导体的临界电流受应力的影响较小。在单层情况下,桥式机械搭接接头的接头电阻可与普通机械搭接接头和焊接搭接接头的接头电阻相媲美。由于未对准,两层搭接接头的接头电阻比单层搭接接头的接头电阻大两倍或三倍。为解决此问题,应在接头部分插入顺应性金属层。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号