首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Evaluation of NbTi Superconducting Joints for 400 MHz NMR Magnet
【24h】

Evaluation of NbTi Superconducting Joints for 400 MHz NMR Magnet

机译:用于400 MHz NMR磁体的NbTi超导接头的评估

获取原文
获取原文并翻译 | 示例

摘要

Persistent current NbTi superconducting joint were fabricated based on the cold-pressing welding method for 400 MHz nuclear magnetic resonance (NMR) magnet. The electrical properties of the joints were tested using the current decay measurement method. To simulate the actual coil assembly, a nine-joint series loop was made and tested. Test results show that the total resistance of the nine persistent joints made based on cold-pressing welding method is 3×10-14 Ω at 120 A under 1 T background magnetic field, which meets the requirements of the 400 MHz NMR magnet. We have found that the induced current in the joint loop decays obeying three decay patterns, which is relevant to the flux creep and can be explained with n-value losses in the joint loop. Relaxation of magnetization in persistent current joint loops was also observed under 1 T background magnetic field.
机译:基于冷压焊接法制造了用于400 MHz核磁共振(NMR)磁体的永久性NbTi超导接头。使用电流衰减测量方法测试了接头的电性能。为了模拟实际的线圈组件,制作并测试了九关节串联回路。测试结果表明,在1 T背景磁场下,采用冷压焊接法制作的9个持久接头在120 A时的总电阻为3×10 -14 Ω,满足焊接要求。 400 MHz NMR磁铁。我们发现,联合回路中的感应电流按照三个衰减模式衰减,这与磁通蠕变有关,并且可以用联合回路中的n值损耗来解释。在1 T背景磁场下,还观察到持续电流接头回路中的磁化松弛。