首页> 外文期刊>Applied Energy >Behaviour of a SPD switchable glazing in an outdoor test cell with heat removal under varying weather conditions
【24h】

Behaviour of a SPD switchable glazing in an outdoor test cell with heat removal under varying weather conditions

机译:SPD可切换玻璃在室外测试室中的行为,在不同天气条件下均具有散热功能

获取原文
获取原文并翻译 | 示例
           

摘要

Suspended particle device (SPD) switchable glazing has potential to control transmission of solar radiation in the visible range by changing its transparency from 55% to 5%. Outdoor test cell characterisation of a SPD switchable glazing offered the dynamic solar heat gain coefficient (SHGC) which varied between 0.05 (when opaque) and 0.38 (when transparent). Reduction of maximum temperature rise of 11% and 15% was possible using SPD "transparent" and "opaque" state compared to same area double-glazing. Insulated test cell with water flow heat exchanger was employed to measure the cooling load reduction potential of SPD glazing while its transmission changed from "transparent" to "opaque" state. A cooling load reduction up to 6 kW h for a 0.343 m(3) volume test cell was possible by changing a 0.21 m x 0.28 m SPD glazing transparency from "transparent" to "opaque". Average overall heat transfer coefficient of SPD glazing varied between 5.02 W/m(2) IC and 5.2 W/m(2) IC for two different states. (C) 2016 Elsevier Ltd. All rights reserved.
机译:悬浮粒子装置(SPD)的可切换玻璃窗具有通过将其透明度从55%更改为5%来控制可见光范围内的太阳辐射传输的潜力。 SPD可切换玻璃的室外测试室特性提供了动态太阳热增益系数(SHGC),该系数在0.05(不透明时)和0.38(透明时)之间变化。与相同面积的双层玻璃相比,使用SPD的“透明”和“不透明”状态可以将最大温度升高降低11%和15%。带有水流热交换器的绝缘测试池用于测量SPD玻璃的透射率从“透明”状态更改为“不透明”状态时降低冷却负荷的能力。通过将0.21 m x 0.28 m SPD玻璃窗的透明度从“透明”更改为“不透明”,可以将0.343 m(3)体积的测试电池的冷却负荷降低至6 kWh。对于两种不同的状态,SPD玻璃的平均总传热系数在5.02 W / m(2)IC和5.2 W / m(2)IC之间变化。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Applied Energy》 |2016年第15期|695-706|共12页
  • 作者单位

    Dublin Inst Technol, Dublin Energy Lab, Dublin, Ireland;

    Dublin Inst Technol, Dublin Energy Lab, Dublin, Ireland;

    Dublin Inst Technol, Dublin Energy Lab, Dublin, Ireland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Glazing; SPD; SHGC; Cooling load; Test cell;

    机译:玻璃;SPD;SHGC;冷却负荷;测试室;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信