首页> 外文期刊>IEEE Transactions on Antennas and Propagation >A Dual-Circular-Polarized Endoscopic Antenna With Wideband Characteristics and Wireless Biotelemetric Link Characterization
【24h】

A Dual-Circular-Polarized Endoscopic Antenna With Wideband Characteristics and Wireless Biotelemetric Link Characterization

机译:具有宽带特性和无线生物电动仪表表征的双圆偏振内窥镜天线

获取原文
获取原文并翻译 | 示例

摘要

In this article, the first-ever dual-circular-polarized wideband conformal endoscopic antenna is designed at the medical implant communication service band (402 MHz) and industrial, scientific, and medical bands (915 MHz and 2.4 GHz). The proposed antenna with a small footprint of 8 mm(3) (32 mm x 10 mm x 0.025 mm) is printed on flexible polyamide and wrapped onto the inner wall of the capsule to spare the space for the capsule integrated components. For evaluation of the antenna's performance within a full-package endoscopic device, a homogeneous muscle box and realistic Duke human phantoms were used. For measurement, the fabricated antenna is enclosed inside a 3-D-printed capsule along with the endoscopic system, and the enclosed system is waterproofed. The S-parameters and radiation patterns are measured in a saline-filled American Society for Testing and Materials (ASTM) model and a minced-pork phantom. The measured impedance bandwidths and gains at 402 MHz, 915 MHz, and 2.4 GHz are 236.2%, 104%, and 55.4% and -29.71, -28.7, and -20.8 dBi, respectively. The measured axial-ratio bandwidths are 45.9% and 21.3% at 915 MHz and 2.4 GHz, respectively. Furthermore, the link budget is numerically analyzed and measured via real-time telemetry using software-defined radios. The proposed antenna complies well with the human safety standards and satisfies the range and high data-rate requirements.
机译:在本文中,第一次双圆极化宽带共形内窥镜天线设计在医疗植入式通信服务频段(402MHz)和工业,科学和医用频段(915MHz和2.4GHz)中设计。在柔性聚酰胺上印刷具有8mm(3)(32mm×10mm×0.025mm)的小占地面积的所提出的天线,并缠绕在胶囊的内壁上以备用胶囊集成部件的空间。为了评估天线在全包内窥镜装置内的性能,使用均匀的肌肉盒和现实的公爵人体模子。为了测量,制造的天线与内窥镜系统一起封闭在3-D印刷的胶囊内,并且封闭的系统防水。 S参数和辐射模式在良好的美国用于测试和材料(ASTM)模型和碎猪肉幻影中测量。测量的阻抗带宽和402MHz,915MHz和2.4GHz的增益分别为236.2%,104%和55.4%和-29.71,-28.7和-20.8 dBi。测量的轴向比带宽分别为915 MHz和2.4GHz的45.9%和21.3%。此外,通过使用软件定义的无线电通过实时遥测进行数值分析和测量链路预算。建议天线符合人类安全标准,满足范围和高数据速率要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号