The entry condition of the Severe Accident Management Guideline (SAMG) for APR1400 has been evaluated on the basis of the Core Exit Temperature (CET) and Peak Cladding Temperature (PCT) calculated by the MARS-KS code. Although the APR1400 is a new type of reactor in Korea, it has been used the same entry condition to the SAMG as the former version of reactor. This study models the APR1400 with a system analysis code, i.e., the MARS-KS code. Then three initiating events which contribute 80 percent to the Core Damage Frequency (CDF) are selected as reference accidents to figure out the validity of the entry condition: Station Black-Out (SBO), Small- and Medium-Break Loss-Of-Coolant-Accidents (SBLOCA and MBLOCA). In order to verify the SAMG entry condition, the times to three important points, i.e., the current SAMG entry point (CET 923K), effective transition point, and fuel damage point (PCT 1255K) have been compared for each scenario. The conclusion reveals that the current SAMG entry condition properly indicates the fuel damage point and effective transition point for the events.
机译:已根据MARS-KS代码计算的堆芯出口温度(CET)和峰值包层温度(PCT)对APR1400的严重事故管理指南(SAMG)的进入条件进行了评估。尽管APR1400是韩国的一种新型反应堆,但它在SAMG中的使用条件与以前版本的反应堆相同。本研究使用系统分析代码(即MARS-KS代码)对APR1400进行建模。然后,选择对核心损坏频率(CDF)贡献80%的三个启动事件作为参考事故,以确定进入条件的有效性:站点停电(SBO),中小型冷却损失-事故(SBLOCA和MBLOCA)。为了验证SAMG进入条件,已比较了每种情况下三个重要点的时间,即当前SAMG进入点(CET 923K),有效过渡点和燃料损坏点(PCT 1255K)。结论表明,当前SAMG进入条件正确指示了事件的燃油损坏点和有效过渡点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号