摘要

An electrospray ionization tandem mass spectrometric (ESI-MS-MS) method has been developed for the determination of cyanide (CN–) in blood. Five microliters of blood was hemolyzed with 50 μL of water, then 5 μL of 1 M tetramethylammonium hydroxide solution was added to raise the pH of the hemolysate and to liberate CN– from methemoglobin. CN– was then reacted with NaAuCl4 to produce dicyanogold, Au(CN)2–, that was extracted with 75 μL of methyl isobutyl ketone. Ten microliters of the extract was injected directly into an ESI-MS-MS instrument and quantification of CN– was performed by selected reaction monitoring of the product ion CN– at m/z 26, derived from the precursor ion Au(CN)2– at m/z 249. CN– could be measured in the quantification range of 2.60 to 260 μg/L with the limit of detection at 0.56 μg/L in blood. This method was applied to the analysis of clinical samples and the concentrations of CN– in the blood were as follows: 7.13 ± 2.41 μg/L for six healthy non-smokers, 3.08 ± 1.12 μg/L for six CO gas victims, 730 ± 867 μg for 21 house fire victims, and 3,030 ± 97 μg/L for a victim who ingested NaCN. The increase of CN– in the blood of a victim who ingested NaN3 was confirmed using MS-MS for the first time, and the concentrations of CN– in the blood, gastric content and urine were 78.5 ± 5.5, 11.8 ± 0.5, and 11.4 ± 0.8 μg/L, respectively.
机译:已经开发出一种电喷雾电离串联质谱(ESI-MS-MS)方法,用于测定血液中的氰化物(CN – )。用50μL的水将5微升的血液溶血,然后加入5μL的1 M氢氧化四甲铵溶液以提高溶血液的pH值并从高铁血红蛋白中释放出CN – 。然后将CN – 与NaAuCl 4 反应生成二氰基金Au(CN) 2 ,将其提取含75μL甲基异丁基酮。将十微升提取物直接注入ESI-MS-MS仪器中,通过选择对产物离子CN -的反应监测,以m / m进行CN – 的定量z 26,源自前体离子Au(CN) 2 ,m / z249。CN – 可以在定量范围内测量的检测限为2.60至260μg/ L,血液中检出限为0.56μg/ L。该方法用于临床样品的分析,血液中CN – 的浓度如下:6名健康非吸烟者为7.13±2.41μg/ L,6名健康非吸烟者为3.08±1.12μg/ L。 6名CO气体受害者,其中21名房屋火灾受害者为730±867μg/ L,摄入NaCN的受害者为3030±97μg/ L。首次使用MS-MS确认了摄入NaN 3 的受害人血液中CN – 的增加,并且CN – 血液,胃和尿中的含量分别为78.5±5.5、11.8±0.5和11.4±0.8μg/ L。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号