...
首页> 外文期刊>American Journal of Neuroradiology >Retrograde Flow in the Left Inferior Petrosal Sinus and Blood Steal of the Cavernous Sinus Associated with Central Vein Stenosis: MR Angiographic Findings
【24h】

Retrograde Flow in the Left Inferior Petrosal Sinus and Blood Steal of the Cavernous Sinus Associated with Central Vein Stenosis: MR Angiographic Findings

机译:左下肾窦窦逆行血流与中央静脉狭窄相关的海绵窦血窃:MR血管造影结果。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND AND PURPOSE: We attempted to identify the cause of abnormal venous flow seen during arterial MR angiography in the inferior petrosal sinus by use of in three female patients (aged 51, 48, and 70 years, respectively). METHODS: Arterial 3D time-of-flight MR angiography was performed with a tilted optimized nonsaturating excitation pulse sequence (TR/TE, 31/7; flip angle, 20 degrees; section thickness, 65 mm; effective thickness, 1 mm; number of sections, 1 to 2); no magnetization transfer pulse sequence was used. Contrast-enhanced 3D MR angiography of the neck was performed with a 3D fast low-angle shot pulse sequence (TR/TE, 4.6/1.8; flip angle, 40 to 45 degrees; section thickness, 80 mm; intersection gap, 1.5 mm; acquisition matrix, 180 x 256; acquisition time, 27 s) on a system with a whole-body coil. RESULTS: In all three patients, 3D time-of-flight MR angiography revealed abnormal vascular signal originating from the left cavernous sinus, continuing through the inferior petrosal sinus, and ending in the proximal internal jugular vein at the jugular bulb level. Abnormal vascular signal at the jugular bulb, sluggish flow and flow-related enhancement in the left internal jugular vein, and signal void in the contralateral jugular vein were noted. Contrast-enhanced delayed-phase MR angiography showed stenosis in the left brachiocephalic vein in all patients. CONCLUSION: High signal intensity noted at the inferior petrosal sinus resulted from retrograde flow. Retrograde flow was due to blood stealing from the internal jugular vein toward the cavernous sinus because of venous stenosis in the brachiocephalic vein.
机译:背景与目的:我们试图通过在三名女性患者中使用 在动脉MR血管造影术中发现 静脉血流异常的原因sup>(分别为51、48和70岁)。 方法:采用倾斜的优化非饱和激发脉冲序列进行动脉3D飞行时间MR血管造影。 (TR / TE为31/7;翻转角为20度;截面厚度为65 mm;有效厚度为1 mm;截面数为1至2); 未使用磁化传递脉冲序列。使用3D快速低角度 发射脉冲序列(TR / TE,4.6 / 1.8;翻转角40至45)执行颈部对比度 的3D MR颈部血管造影度; 截面厚度,80毫米;相交间隙,1.5毫米;采集 矩阵,180 x 256;采集时间,27 s),系统 揭示了源自左侧的异常血管信号 海绵状窦,延伸穿过下颌窦, ,并在颈 球水平处终止于近颈内静脉。颈内球的异常血管信号,左颈内 静脉的 血流缓慢和与血流有关的增强,以及对侧颈静脉内的信号空洞为 注意到。对比增强的延迟期MR血管造影显示所有患者的左臂头静脉狭窄 结论:下睑板 信号强度高窦是逆行血流造成的。逆行血流是由于肱头颅静脉中的静脉狭窄导致从颈内静脉向海绵状窦的血液窃取所致。 < / sup>

著录项

  • 来源
    《American Journal of Neuroradiology》 |2003年第7期|00001364-00001368|共5页
  • 作者单位

    Ultra G?rüntüleme Merkezi (Imaging Center);

    Sel?uk University School of Medicine, Department of Neurology, Konya, Turkey;

    Sel?uk University School of Medicine, Department of Neurology, Konya, Turkey;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号