首页> 外文期刊>Advances in Health Sciences Education >Using signal detection theory to model changes in serial learning of radiological image interpretation
【24h】

Using signal detection theory to model changes in serial learning of radiological image interpretation

机译:使用信号检测理论对放射学图像解释序列学习中的变化建模

获取原文
获取原文并翻译 | 示例
           

摘要

Signal detection theory (SDT) parameters can describe a learner’s ability to discriminate (d′) normal from abnormal and the learner’s criterion (λ) to under or overcall abnormalities. To examine the serial changes in SDT parameters with serial exposure to radiological cases. 46 participants were recruited for this study: 20 medical students (MED), 6 residents (RES), 12 fellows (FEL), 5 staff pediatric emergency physicians (PEM), and 3 staff radiologists (RAD). Each participant was presented with 234 randomly assigned ankle radiographs using a web-based application. Participants were given a clinical scenario and considered 3 views of the ankle. They classified each case as normal or abnormal. For abnormal cases, they specified the location of the abnormality. Immediate feedback included highlighting on the images and the official radiologist’s report. The low experience group (MED, RES, FEL) showed steady improvement in discrimination ability with each case, while the high experience group (PEM, RAD) had higher and stable discrimination ability throughout the exercise. There was also a difference in the way the high and low experience groups balanced sensitivity and specificity (λ) with the low experience group tending to make more errors calling positive radiographs negative. This tendency was progressively less evident with each increase in expertise level. SDT metrics provide valuable insight on changes associated with learning radiograph interpretation, and may be used to design more effective instructional strategies for a given learner group.
机译:信号检测理论(SDT)参数可以描述学习者区分(d')正常与异常以及学习者的标准(λ)到欠佳或过高异常的能力。在连续暴露于放射病例的情况下检查SDT参数的连续变化。这项研究招募了46名参与者:20名医学生(MED),6名住院医师(RES),12名研究员(FEL),5名职员儿科急诊医师(PEM)和3名职员放射线医师(RAD)。使用基于Web的应用程序为每个参与者提供了234个随机分配的脚踝X光片。给予参与者临床情况并考虑了踝部的3个视图。他们将每种情况分为正常或异常。对于异常情况,他们指定了异常的位置。即时反馈包括突出显示图像和放射科医生的官方报告。低经验组(MED,RES,FEL)在每种情况下均显示出辨别能力的稳定提高,而高经验组(PEM,RAD)在整个运动过程中均具有较高且稳定的辨别能力。高经验团队和低经验团队平衡敏感性和特异性(λ)的方式也有所不同,低经验团队倾向于做出更多的错误,称阳性X光片为阴性。随着专业水平的提高,这种趋势逐渐不明显。 SDT度量标准提供了有关与学习射线照相解释相关的变化的宝贵见解,并可用于为给定的学习者群体设计更有效的指导策略。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号