首页> 美国卫生研究院文献>Thorax >Effects of breathing pattern and inspired air conditions on breath condensate volume pH nitrite and protein concentrations
【2h】

Effects of breathing pattern and inspired air conditions on breath condensate volume pH nitrite and protein concentrations

机译:呼吸方式和呼吸条件对呼吸凝结水量pH亚硝酸盐和蛋白质浓度的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: The effects of breathing pattern and inspired air conditions on the volume and content of exhaled breath condensate (EBC) were investigated. >Methods: Total exhaled water (TEW), EBC volume, pH, nitrite and protein concentrations were measured in three groups of 10 healthy subjects breathing into a condenser at different target minute ventilations (Vm), tidal volumes (Vt), and inspired air conditions. >Results: The volumes of both TEW and EBC increased significantly with Vm. For Vm 7.5, 15 and 22.5 l/min, mean (SD) EBC was 627 (258) µl, 1019 (313) µl, and 1358 (364) µl, respectively (p<0.001) and TEW was 1879 (378) µl, 2986 (496) µl, and 4679 (700) µl, respectively (p<0.001). TEW was significantly higher than EBC, reflecting a condenser efficiency of 40% at a target Vm of 7.5 l/min which reduced to 29% at Vm 22.5 l/min. Lower Vt gave less TEW than higher Vt (26.6 v 30.7 µl/l, mean difference 4.1 (95% CI 2.6 to 5.6), p<0.001) and a smaller EBC volume (4.3 v 7.6 µl/l, mean difference 3.4 (95% CI 2.3 to 4.5), p<0.001). Cooler and drier inspired air yielded less water vapour and less breath condensate than standard conditions (p<0.05). Changes in the breathing pattern had no effect on EBC protein and nitrite concentrations and pH. >Conclusion: These results show that condensate volume can be increased by using high Vt and increased Vm without compromising the dilution of the sample.
机译:>背景:研究了呼吸方式和吸入空气条件对呼出气冷凝物(EBC)的体积和含量的影响。 >方法:在不同目标分钟通气量(Vm),潮气量下,由10名健康受试者组成的三组呼吸10例健康受试者,测量了总呼出水(TEW),EBC量,pH,亚硝酸盐和蛋白质浓度。 Vt),以及启发性的空调。 >结果:随着Vm的增长,TEW和EBC的数量均显着增加。对于Vm 7.5、15和22.5 l / min,平均(SD)EBC为627(258)μl,1019(313)μl和1358(364)μl(TE)为1879(378)μl ,2986(496)µl和4679(700)µl(p <0.001)。 TEW显着高于EBC,反映了在目标Vm为7.5 l / min时冷凝器效率为40%,在Vm 22.5 l / min时降至29%。较低的Vt给出的TEW低于较高的Vt(26.6 v 30.7 µl / l,平均差异4.1(95%CI 2.6至5.6),p <0.001)和较小的EBC体积(4.3 v 7.6 µl / l,平均差异3.4(95) %CI 2.3至4.5),p <0.001)。与标准条件相比,凉爽干燥的空气产生的水蒸气更少,呼吸冷凝物更少(p <0.05)。呼吸方式的改变对EBC蛋白,亚硝酸盐浓度和pH值没有影响。 >结论:这些结果表明,通过使用高Vt和增加Vm可以增加冷凝液体积,而不会影响样品的稀释度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号