首页> 美国卫生研究院文献>Springer Open Choice >A novel method to reduce noise in electroretinography using skin electrodes: a study of noise level inter-session variability and reproducibility
【2h】

A novel method to reduce noise in electroretinography using skin electrodes: a study of noise level inter-session variability and reproducibility

机译:一种使用皮肤电极减少视网膜电图中噪声的新方法:噪声级会话间可变性和可再现性的研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

To determine the feasibility of recording reproducible electroretinograms (ERGs) with skin electrodes using a new ERG system. Seventeen healthy volunteers were studied. The dark-adapted, bright-flash ERGs were recorded with a new ERG recording system (LE-4000, Tomey, Nagoya, Japan) in which the stimulus alternated between the eyes every 15 s, and each eye was stimulated eight times. The active skin electrode was placed on the lower eyelids of both eyes. The voltage changes of the non-stimulated eye were subtracted from that of the stimulated eye to try to increase the signal-to-noise ratio for eight stimulus cycles. The noise levels were measured from 12 subjects with and without the subtraction steps. ERGs were also recorded on five different days from five subjects, and the coefficient of variation (CV) and the intra-class correlation coefficients (ICCs) were calculated. The noise level without the subtraction step was 18.4 ± 8.4 μV, and it was significantly reduced to 13.8 ± 4.0 μV with the subtraction step (P = 0.001). Reproducible ERGs were obtained from each subject, and the average CV for the five subjects was 6.1 % for the a-wave amplitude, 7.7 % for the b-wave amplitude, and 7.7 % for the sum of the oscillatory potential (OP) amplitude. The ICC was 0.76 for the a-wave amplitude, 0.68 for the b-wave amplitude, and 0.72 for the sum of the OPs amplitude. These findings indicate that our new ERG recording methods shows noise reduction and good reproducibility with low inter-session variability even with skin electrodes.
机译:为了确定使用新的ERG系统使用皮肤电极记录可再现的视网膜电图(ERG)的可行性。研究了十七名健康志愿者。使用新的ERG记录系统(LE-4000,Tomey,名古屋,日本)记录了适应黑暗的,明亮闪光的ERG,该刺激每15秒钟在眼睛之间交替刺激一次,每只眼睛被刺激八次。活性皮肤电极放置在两只眼睛的下眼睑上。从受刺激的眼睛中减去未受刺激的眼睛的电压变化,以尝试在八个刺激周期中增加信噪比。测量了有和没有减法步骤的12名受试者的噪声水平。还从五个对象的五个不同日期记录了ERG,并计算了变异系数(CV)和组内相关系数(ICC)。没有减法步骤的噪声水平为18.4±8.4μV,通过减法步骤将噪声水平显着降低至13.8±4.0μV(P = 0.001)。从每位受试者获得可再现的ERG,五位受试者的平均CV为a波振幅的6.1%,b波振幅的7.7%和振荡电位(OP)振幅之和的7.7%。对于a波振幅,ICC为0.76,对于b波振幅,ICC为0.68,对于OP振幅之和,ICC为0.72。这些发现表明,我们的新型ERG记录方法即使在使用皮肤电极的情况下,也显示出降噪效果和良好的重现性,并且会话间的可变性也较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号