Biological samples present a range of complexities from homogeneous purified protein to multicomponent mixtures. Accurate qualification of such samples is paramount to downstream applications. We describe the development of an MIR spectroscopy-based analytical method offering simultaneous protein quantitation (0.25–5 mg/mL) and analysis of total lipid or detergent species, as well as the identification of other biomolecules present in biological samples. The method utilizes a hydrophilic PTFE membrane engineered for presentation of aqueous samples in a dried format compatible with fast infrared analysis. Unlike classical quantification techniques, the reported method is amino acid sequence independent and thus applicable to complex samples of unknown composition. By comparison to existing platforms, this MIR-based method enables direct quantification using minimal sample volume (2 µL); it is well-suited where repeat access and limited sample size are critical parameters. Further, accurate results can be derived without specialized training or knowledge of IR spectroscopy. Overall, the simplified application and analysis system provides a more cost-effective alternative to high-throughput IR systems for research laboratories with minimal throughput demands. In summary, the MIR-based system provides a viable alternative to current protein quantitation methods; it also uniquely offers simultaneous qualification of other components, notably lipids and detergents.
机译:生物样品呈现出从均一的纯化蛋白质到多组分混合物的一系列复杂性。此类样品的准确鉴定对下游应用至关重要。我们描述了一种基于MIR光谱的分析方法的发展,该方法可同时进行蛋白质定量(0.25-5 mg / mL)和分析总脂质或去污剂种类,以及鉴定生物样品中存在的其他生物分子。该方法利用了一种亲水性PTFE膜,该膜经过工程设计可以以干燥的形式呈现水性样品,并与快速红外分析兼容。与经典的定量技术不同,所报道的方法与氨基酸序列无关,因此适用于未知组成的复杂样品。与现有平台相比,这种基于MIR的方法可使用最少的样品量(2µL)进行直接定量;它非常适合重复访问和有限的样本量是关键参数的情况。此外,无需经过专门培训或不具备红外光谱知识,就可以得出准确的结果。总体而言,简化的应用程序和分析系统为吞吐量最小的研究实验室提供了一种比高通量红外系统更具成本效益的替代方案。总而言之,基于MIR的系统为当前蛋白质定量方法提供了可行的替代方法。它还独特地同时鉴定其他成分,特别是脂质和去污剂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号