首页> 美国卫生研究院文献>International Journal of Exercise Science >Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy
【2h】

Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy

机译:利用单频生物电阻抗分析和生物阻抗谱评估热量对人体水的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study was to determine if heat exposure alters the measures of total body water (TBW), extracellular water (ECW), and intracellular water (ICW) in both single-frequency bioelectrical impedance analysis (BIA) and bioimpedance spectroscopy (BIS). Additionally, we sought to determine if any differences exist between the BIA and BIS techniques before and after brief exposure to heat. Body water was evaluated for twenty men (age=24±4 years) in a thermoneutral environment (22°C) before (PRE) and immediately after (POST) 15 min of passive heating (35°C) in an environmental chamber. The mean difference and 95% limits of agreement at PRE demonstrated that BIS yielded significantly higher body water values than BIA (all p<0.05; TBW=1.8kg; ECW=0.6±1.3kg; ICW=1.2±3.7kg). However, the effect size (ES) of the mean differences at PRE were small and the r-values were high (r≥0.97). TBW and ICW remained significantly higher at POST for BIS (both p<0.05; 1.4±3.2kg and 1.1±3.7kg, respectively) whereas ECW was not different (p>0.05; 0.2±1.5kg). Additionally, the ES of the mean differences at POST were trivial to small and the r-values were high (r≥0.96). When analyzing the changes in body water before and after heat exposure, POST values for BIS were significantly higher than PRE (all p<0.001; TBW=0.6±0.8kg; ECW=0.4±0.3kg; ICW=0.3±0.6kg). Similarly, POST values for BIA were significantly higher than PRE (all p<0.001; TBW=1.0±0.6kg; ECW=0.7±0.4kg; ICW=0.4±0.4kg). BIA and BIS provide similar body water estimates. However, the increase in POST body water values indicate more research is needed before either method can be used for estimating body water after heat exposure.
机译:这项研究的目的是确定在单频生物电阻抗分析(BIA)和生物阻抗谱(BIS)中热量暴露是否会改变人体总水(TBW),细胞外水(ECW)和细胞内水(ICW)的测量值)。此外,我们试图确定短暂暴露于热之前和之后BIA和BIS技术之间是否存在差异。在(PRE)之前和之后(POST)在环境室内进行被动加热(35°C)15分钟后,在热中性环境(22°C)中评估了二十个人(年龄= 24±4岁)的体内水。 PRE的平均差异和协议的95%限制表明,BIS的体内水分值明显高于BIA(所有p <0.05; TBW = 1.8kg; ECW = 0.6±1.3kg; ICW = 1.2±3.7kg)。但是,PRE均值差异的影响大小(ES)小,r值高(r≥0.97)。 BIS的POST时TBW和ICW仍显着较高(分别为p <0.05; 1.4±3.2kg和1.1±3.7kg),而ECW则无差异(p> 0.05; 0.2±1.5kg)。此外,POST的平均差异的ES很小,很小,r值很高(r≥0.96)。分析热量暴露前后的体内水变化时,BIS的POST值显着高于PRE(所有p <0.001; TBW = 0.6±0.8kg; ECW = 0.4±0.3kg; ICW = 0.3±0.6kg)。同样,BIA的POST值显着高于PRE(所有p <0.001; TBW = 1.0±0.6kg; ECW = 0.7±0.4kg; ICW = 0.4±0.4kg)。 BIA和BIS提供相似的人体水分估算。但是,POST人体水分含量的增加表明,在使用任何一种方法估算暴露于热后的人体水分之前,还需要进行更多的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号