A simple RP-HPLC-PDA method for determination of atenolol (ATN) and trimetazidine (TMZ) in human urine and tablets has been developed. Analytes were separated on a Caltrex BI column (125× 4.0 mm, 5 μm) with 25mM potassium dihydrogen phosphate pH 3.3, methanol, and acetonitrile mobile phases. The PDA detector was operated at 210 nm for TMZ and 225 nm for ATN and the flow rate was 1.0 mL/ min. Linearity was obtained over a concentration range of (1.0-100 μg/mL) for both analytes in standard solutions and the method was successfully applied for determination of target analytes in their pharmaceutical tablets. Excellent linearity was also obtained over concentration ranges of (0.25-25 μg/mL) and (0.5-25 μg/mL) in human urine for TMZ and ATN, respectively. A simple liquid-liquid extraction was applied for urine sample clean-up and a gradient method was used for chromatographic separation. The lower limit of quantitation (LOQ) was 0.99 and 0.60 μg/mL for ATN and TMZ, respectively. The limit of detection (LOD) was 0.30 and 0.18 μg/mL for ATN and TMZ, respectively. Inter- and intraday precision and accuracy for ATN were within ±1.89% in pure form and within ±2.85% in urine samples. Inter- and intraday precision and accuracy for TMZ were within ± 3.99% in pure form and within ± 3.19% in urine samples.
机译:开发了一种简单的RP-HPLC-PDA方法,用于测定人尿液和片剂中的阿替洛尔(ATN)和曲美他嗪(TMZ)。在带有25mM磷酸二氢钾pH 3.3,甲醇和乙腈流动相的Caltrex BI柱(125×4.0 mm,5μm)上分离分析物。 PDA检测器的TMZ工作波长为210 nm,ATN的工作波长为225 nm,流速为1.0 mL / min。在标准溶液中两种分析物的浓度范围(1.0-100μg/ mL)均具有线性,该方法已成功用于测定其药物片剂中的目标分析物。在人尿中TMZ和ATN的浓度范围分别为(0.25-25μg/ mL)和(0.5-25μg/ mL)时,也获得了出色的线性。简单的液-液萃取用于尿液样品净化,梯度法用于色谱分离。 ATN和TMZ的定量下限(LOQ)分别为0.99和0.60μg/ mL。 ATN和TMZ的检出限(LOD)分别为0.30和0.18μg/ mL。纯净形式的ATN的日间和日内精度和准确度在±1.89%以内,在尿液样本中为±2.85%。纯净形式的TMZ的日间和日内精度和准确度在±3.99%以内,尿液样本中在±3.19%以内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号