Peritoneal dialysis effluent (PDE) potentially carries an archive of peptides relevant to pathological processes in abdominal and surrounding tissues. Magnetic beads and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry is one such approach that offers a unique tool for profiling of peptides, but this approach has not been used in the PDE analysis. In this study, we developed a strategy for screening PDE proteins <15 kDa and applied this technique to identify potential biomarkers for peritonitis. We examined four kinds of magnetic beads, including a carbon series (C3, C8), weak cation exchange (WCX) and immobilized metal-affinity chromatography (IMAC-Cu) beads. Samples processed with IMAC-Cu magnetic beads consistently showed more MS signals across all beads within the measured mass range. Moreover, there was no difference in the number and morphology of MS signals between concentrated and unconcentrated samples. The PDE peptidome pattern, based on a panel of 15 peaks, accurately recognized peritonitis PD patients from peritonitis-free patients with sensitivity of 90.5% and specificity of 94.7% respectively. Therefore, IMAC-Cu magnetic beads and unconcentrated samples can be used as a fast and cost-effective approach for sample preparation prior to more in-depth discovery of predictive biomarkers of disease in patients on dialysis.
机译:腹膜透析流出物(PDE)可能携带与腹部和周围组织的病理过程相关的肽档案。磁珠和基质辅助激光解吸/电离飞行时间质谱法是一种这样的方法,它提供了用于肽谱分析的独特工具,但该方法尚未用于PDE分析中。在这项研究中,我们开发了一种筛选<15 kDa的PDE蛋白的策略,并将该技术应用于识别腹膜炎的潜在生物标志物。我们检查了四种磁珠,包括碳系列(C3,C8),弱阳离子交换(WCX)和固定化金属亲和色谱(IMAC-Cu)珠。用IMAC-Cu磁珠处理的样品始终在测量质量范围内的所有磁珠上显示出更多的MS信号。而且,浓缩样品和未浓缩样品之间MS信号的数量和形态没有差异。基于一组15个峰的PDE肽组模式可准确识别无腹膜炎患者的腹膜炎PD患者,其敏感性分别为90.5%和94.7%。因此,在更深入地发现透析患者的疾病预测生物标志物之前,IMAC-Cu磁珠和未浓缩样品可用作制备样品的快速且经济高效的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号