首页> 美国卫生研究院文献>International Journal of Veterinary Science and Medicine >Two-dimensional shear wave elastography of liver in healthy dogs: anaesthesia as a source of variability
【2h】

Two-dimensional shear wave elastography of liver in healthy dogs: anaesthesia as a source of variability

机译:健康狗肝脏的二维剪切波弹性成像:麻醉是变异性的来源

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Two-dimensional shear wave elastography (2D-SWE) is a non-invasive method to quantitatively evaluate the liver stiffness (LS), allowing the detection of hepatic pathological changes in both dogs and humans. In dogs, some factors such as patient movement and respiration can cause artefacts and potential errors of measurements. Therefore, anaesthesia has been suggested to reduce the effect of the movement on 2D-SWE in dogs. This study was performed to evaluate the influence of an anaesthetic protocol on 2D-SWE measurements for assessment of LS in healthy dogs. Forty-five dogs were included and subjected to anaesthesia: in 11 dogs, the 2D-SWE was performed both before and under anaesthesia, in 19 dogs, the 2D-SWE was performed only when they were awake and in 15 dogs, the examination was carried out only under anaesthesia. The anaesthetic protocol was composed of intramuscular injection of a combination of dexmedetomidine, methadone and ketamine and intravenous administration of propofol for induction and isoflurane for maintenance. The variability of 2D-SWE values according to anaesthesia was evaluated. Median 2D-SWE values were significantly higher in anesthetized dogs compared to awake dogs either by considering separately the dogs in which the examination was performed both awake and under anaesthesia and by considering all dogs included. According to our study, anaesthesia helped to avoid challenges related to patient movement and respiration; however, it was a source of variability on 2D-SWE values, and this factor should be considered before performing 2D-SWE under anaesthesia.
机译:二维剪切波弹性成像 (2D-SWE) 是一种定量评估肝脏硬度 (LS) 的非侵入性方法,可以检测狗和人类的肝脏病理变化。在狗中,一些因素(例如患者的运动和呼吸)会导致伪影和潜在的测量误差。因此,有人建议麻醉以减少运动对狗 2D-SWE 的影响。进行这项研究是为了评估麻醉方案对 2D-SWE 测量的影响,以评估健康狗的 LS。包括 45 只狗并接受麻醉:在 11 只狗中,在麻醉前和麻醉下进行 2D-SWE,在 19 只狗中,仅在清醒时进行 2D-SWE,在 15 只狗中,仅在麻醉下进行检查。麻醉方案包括肌肉注射右美托咪定、美沙酮和氯胺酮的组合,以及静脉注射异丙酚诱导和异氟醚维持。根据麻醉评估 2D-SWE 值的变异性。与清醒的狗相比,麻醉狗的中位 2D-SWE 值显着更高,要么单独考虑清醒和麻醉下进行检查的狗,要么考虑包括所有狗。根据我们的研究,麻醉有助于避免与患者运动和呼吸相关的挑战;然而,这是 2D-SWE 值变化的来源,在麻醉下进行 2D-SWE 之前应考虑这一因素。

著录项

代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号