首页> 美国卫生研究院文献>Journal of Clinical and Experimental Dentistry >Chemomechanical preparation by hand instrumentation and by Mtwo engine-driven rotary files an ex vivo study
【2h】

Chemomechanical preparation by hand instrumentation and by Mtwo engine-driven rotary files an ex vivo study

机译:通过手动仪器进行化学机械制备以及由Mtwo发动机驱动的旋转锉刀进行的离体研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective: To compare the disinfecting efficacy of the sodium hypochlorite irrigation by root canal preparation with stainless steel hand files, taper 0.02 and nickel-titanium Mtwo files with taper 0.04-0.06. Study Design: 40 extracted human teeth were sterilized, and then inoculated with Enterococcus faecalis (ATCC 29212). After 6 day incubation time the root canals were prepared by hand with K-files (n=20) and by engine-driven Mtwo files (VDW, Munich, Germany) (n=20). Irrigation was carried out with 2.5% NaOCl in both cases. Samples were taken and determined in colony forming units (CFU) from the root canals before and after the preparation with instruments #25 and #35. Results: Significant reduction in bacterial count was determined after filing at both groups. The number of bacteria kept on decreasing with the extension of apical preparation diameter. There was no significant difference between the preparation sizes in the bacterial counts after hand or engine-driven instrumentation at the same apical size. Statistical analysis was carried out with Mann-Whitney test, paired t-test and independent sample t-test. Conclusions: Significant reduction in CFU was achieved after the root canal preparation completed with 2.5% NaOCl irrigation, both with stainless steel hand or nickel-titanium rotary files. The root canal remained slightly infected after chemo mechanical preparation in both groups. > Key words:Chemomechanical preparation, root canal disinfection, nickel-titanium, conicity, greater taper, apical size.
机译:目的:比较不锈钢手锉,锥度0.02和镍钛Mtwo锉刀,锥度0.04-0.06的根管预备冲洗次氯酸钠的消毒效果。研究设计:对40颗提取的人类牙齿进行消毒,然后接种粪肠球菌(ATCC 29212)。温育6天后,用K型锉(n = 20)和发动机驱动的Mtwo锉(VDW,慕尼黑,德国)手工制备根管(n = 20)。在两种情况下均用2.5%NaOCl进行灌溉。在用#25和#35仪器制备之前和之后,从根管中取样并以菌落形成单位(CFU)进行测定。结果:两组均在提交文件后确定细菌计数显着减少。随着根尖直径的增加,细菌数量不断减少。在相同的根尖尺寸下,在手动或引擎驱动的器械操作后,细菌计数的制剂尺寸之间没有显着差异。用Mann-Whitney检验,配对t检验和独立样本t检验进行统计分析。结论:用不锈钢手动或镍钛旋转锉刀完成根管预备,用2.5%NaOCl冲洗完成根管后,CFU显着降低。两组进行化学机械准备后,根管仍然受到轻微感染。 >关键词:化学机械制备,根管消毒,镍钛合金,锥度,较大锥度,根尖尺寸。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号