首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Measuring Effects of Two-Handed Side and Anterior Load Carriage on Thoracic-Pelvic Coordination Using Wearable Gyroscopes
【2h】

Measuring Effects of Two-Handed Side and Anterior Load Carriage on Thoracic-Pelvic Coordination Using Wearable Gyroscopes

机译:双手侧和前载载体对胸腔 - 盆腔协调的测量效果使用可穿戴陀螺仪

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Manual carrying of heavy weight poses a major risk for work-related low back injury. Body-worn inertial sensors present opportunities to study the effects of ambulatory work tasks such as load carriage in more realistic conditions. An immediate effect of load carriage is reflected in altered gait kinematics. To determine the effects of load carriage mode and magnitude on gait parameters using body-worn angular rate gyroscopes, two laboratory experiments (n = 9 and n = 10, respectively) were conducted. Participants performed walk trials at self-selected speeds while carrying hand loads in two modes (two-handed side vs. anterior) at four load levels (empty-handed, 4.5 kg, 9.1 kg, and 13.6 kg). Six measures of postural sway and three measures of thoracic-pelvic coordination were calculated from data recorded by four body-worn gyroscopes for 1517 gait cycles. Results demonstrated that, after adjusting for relative walking speed, thoracic-pelvic sway, and movement coordination particularly in the coronal and transverse planes, characterized by gyroscope-based kinematic gait parameters, are systematically altered by the mode of load carriage and load magnitude. Similar trends were obtained for an anthropometrically homogenous (Expt-1) and diverse (Expt-2) sample after adjusting for individual differences in relative walking speed. Measures of thoracic-pelvic coordination and sway showed trends of significant practical relevance and may provide sufficient information to typify alterations in gait across two-handed side vs. anterior load carriage of different load magnitudes. This study contributes to understanding the effects of manual load carriage on thoracic-pelvic movement and the potential application of body-worn gyroscopes to measuring these gait adaptations in naturalistic work settings.
机译:手动承载重量重量对工作相关的低伤害造成的主要风险。身体磨损的惯性传感器现在在更现实的条件下研究载荷工作任务如载荷托运的影响的机会。载荷托架的立即反映在改变的步态运动学中。为了确定使用体磨损角速率陀螺仪的​​载荷模式和幅度在步态参数上的影响,进行了两个实验室实验(分别为n = 9和n = 10)。参与者以自选择的速度进行步行试验,同时在四种载荷水平(空手,4.5kg,9.1kg和13.6 kg)中携带两种模式(双手侧与前部)的手载。六种姿势摇摆措施和三种胸腔盆腔协调测量措施从四个身体磨损陀螺仪记录的数据计算1517个步态周期。结果证明,在调节相对步行速度的情况下,特别是在冠状和横向平面中特别地在基于陀螺仪的运动步态参数的特征在一起,通过负载托架和负载幅度来系统地改变。在调整相对步行速度的个体差异后,为拟核血液均匀(EXPT-1)和不同(EXPT-2)样品获得了类似的趋势。胸盆腔协调的措施和摇摆的趋势显着实际相关性,可以提供足够的信息,以便在双手侧与不同负载量大的前载托架上的步态改变。本研究有助于了解手动载携带对胸盆腔运动的影响以及体磨陀螺的潜在应用,以测量自然工作环境中的这些步态适应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号