首页> 美国卫生研究院文献>Materials >Assessment of Force Retention between Milled Metallic and Ceramic Telescopic Crowns with Different Taper Angles Used for Oral Rehabilitation
【2h】

Assessment of Force Retention between Milled Metallic and Ceramic Telescopic Crowns with Different Taper Angles Used for Oral Rehabilitation

机译:用于口腔康复的不同锥形碾磨金属和陶瓷伸缩冠之间的力滞留的评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The present study assessed the retention forces corresponding to different telescopic systems used in removable prosthetic dentures. The telescopic systems were represented by Co–Cr alloy or zirconia-based primary crowns and Co–Cr secondary crowns. All crowns were manufactured using computer-aided design/computer-aided manufacturing technology (CAD/CAM). Two types of reference abutment teeth (upper canine and first upper molar) were selected in order to obtain the telescopic crowns and two taper angles—of 0° and 2°—were used for the design of the crowns. A number of 120 samples of telescopic crowns were obtained and subjected to mechanical tests, following a specific protocol, on a mechanical testing equipment. The retention of the telescopic systems was evaluated for different sets of cycles (up to 360), represented by movements that simulate the intraoral insertion and disinsertion of the telescopic systems. The present study highlights that the telescopic systems in which the primary crown is made of zirconia ceramics presents more advantages than those made of Co–Cr. All telescopic systems studied, highlighted that by modifying the taper angle from 0° to 2°, the retention forces have decreased, irrespective of the materials used for the fabrication of the primary crown, suggesting that by using a taper angle of 0°, which is known to be ideal, more efficient, and reliable prosthesis can be developed. Thus, even though the ceramic–metallic telescopic system exhibited the highest retention, all telescopic crowns evaluated registered values between 2–7 N, indicating that they are suitable for clinical use.
机译:本研究评估了对应于可拆卸假牙牙本质的不同伸缩系统的保留力。伸缩系统由Co-Cr合金或基于氧化锆的主要冠和Co-Cr二次冠部表示。所有冠部都采用计算机辅助设计/计算机辅助制造技术(CAD / CAM)制造。选择两种类型的参考邻接牙齿(上犬和第一上摩尔)以获得伸缩冠和两个锥形 - 0°和2° - 用于设计冠部。在机械测试设备上,获得了在特定方案之后获得并对机械测试获得的多种120样品进行机械测试。评价伸缩系统的保留,用于不同的循环(最多360),由模拟伸缩系统的口内插入和灭菌的运动表示。本研究突出显示,主要冠部由氧化锆陶瓷制成的伸缩系统具有比由CO-Cr制成的更优点。研究的所有伸缩系统都突出显示,通过将锥角从0°到2°修改,保持力随着用于制造主冠的材料而降低,表明通过使用0°的锥角来提示已知是理想的,更有效,并且可以开发可靠的假体。因此,即使陶瓷金属伸缩系统呈现最高的保留,所有伸缩冠冠均评估了2-7 n之间的注册值,表明它们适合于临床使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号