...
首页> 外文期刊>Srpski Arhiv za Celokupno Lekarstvo >Retention force of overdenture retained with telescopic crowns: A comparison of polyether ether ketone and zirconia ceramic telescopic crowns
【24h】

Retention force of overdenture retained with telescopic crowns: A comparison of polyether ether ketone and zirconia ceramic telescopic crowns

机译:用伸缩冠保留的过度滞留力:聚醚醚酮和氧化锆陶瓷伸缩冠的比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Introduction/Objective. Recently, new materials for double crowns have been introduced, such as zirconia and polyether ether ketone (PEEK). However, some characteristics of these materials, such as retentive force and duration of ?settling in phase,? have not been investigated sufficiently. During the ?settling in phase,? telescopic overdenture has not yet achieved its definitive retention force, and it can be harmful for periodontal tissue if the value is above optimal for a long period of time. The objective was to measure the in vitro overall pull-off force of telescopic crowns where primary crowns were made from zirconia ceramics and a survey of the ?settling in phase? duration. Methods. Forty zirconia primary telescopic crowns were produced on prepared canine teeth. Twenty secondary crowns were of PEEK and other 20 of zirconia with electroplated gold copings. The pull-off force measurements were conducted utilizing a dynamometer until a constant value was obtained. Results. The specimens of the PEEK group showed higher initial retentive force values. Settling in phase was finished between 800 and 900 cycles of separation for both groups. Comparing the value of the pull-off force between individual different cycles, a statistically significant reduction was recorded up to the 800th cycle, while between the 800th and the 900th cycle there was no difference. Conclusions. The settling in phase was finished between 800 and 900 cycles of separation in both groups. Final retentive force values for both tested telescopic groups were in the optimal range which is 5?9 N per one telescopic crown.
机译:介绍/目标。最近,已经引入了用于双冠的新材料,例如氧化锆和聚醚醚酮(PEEK)。但是,这些材料的一些特征,如保持力和持续时间?稳定相位,?尚未充分调查。在阶段,阶段,?伸缩覆盖尚未实现其最终的保留力,如果该值在很长一段时间内最佳最佳值,则可能对牙周组织有害。目的是测量伸缩冠的体外总拉力,主要冠是由氧化锆陶瓷制成的冠冠和阶段调查?期间。方法。在制备的犬齿牙齿上产生四十氧化锆原发性伸缩冠。二十个中冠是窥视和其他20个氧化锆,具有电镀金试。利用测功机进行拉出力测量,直到获得恒定值。结果。 PEEK组标本显示出更高的初始保持力值。两组的阶段沉降在800至900周期之间。比较各个不同周期之间的拉出力的值,记录到第800周期的统计学上显着的减少,而在800和第900周期之间没有差异。结论。在两组中的800至900个分离之间完成了相位的沉降。两种测试伸缩基团的最终保持力值在最佳范围内,每一个伸缩冠的5?9 n。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号