Application of Pelvic Circumferential Compression Devices in Pelvic Ring Fractures—Are Guidelines Followed in Daily Practice?

机译:盆腔周向压缩装置在盆腔骨折中的应用 - 是日常练习中的准则吗?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Early administration of a pelvic circumferential compression device (PCCD) is recommended for suspected pelvic trauma. This study was conducted to evaluate the prevalence of PCCD in patients with pelvic fractures assigned to the resuscitation room (RR) of a Level I trauma center. Furthermore, correct application of the PCCD as well as associated injuries with potential clinical sequelae were assessed. All patients with pelvic fractures assigned to the RR of a level one trauma center between 2016 and 2017 were evaluated retrospectively. Presence and position of the PCCD on the initial trauma scan were assessed and rated. Associated injuries with potential adverse effects on clinical outcome were analysed. Seventy-seven patients were included, of which 26 (34%) had a PCCD in place. Eighteen (23%) patients had an unstable fracture pattern of whom ten (56%) had received a PCCD. The PCCD was correctly placed in four (15%) cases, acceptable in 12 (46%) and incorrectly in ten (39%). Of all patients with pelvic fractures (n = 77, 100%) treated in the RR, only one third (n = 26, 34%) had a PCCD. In addition, 39% of PCCDs were positioned incorrectly. Of the patients with unstable pelvic fractures (n = 18, 100%), more than half either did not receive any PCCD (n = 8, 44%) or had one which was inadequately positioned (n = 2, 11 %). These results underline that preclinical and clinical education programs on PCCD indication and application should be critically reassessed.
机译:推荐用于疑似骨盆创伤的早期施用盆腔压缩装置(PCCD)。进行该研究以评估分配给I级创伤中心的复苏室(RR)的骨盆骨折患者中PCCD的患病率。此外,评估了对潜在临床后遗症的PCCD以及相关损伤的正确施用。回顾性评估所有患有盆腔骨折的患者,分配给2016年至2017年间的一个创伤中心的RR。评估和评定PCCD对初始创伤扫描的情况和位置。分析了对临床结果潜在不利影响的相关伤害。包括七十七名患者,其中26(34%)有PCCD。十八(23%)患者具有不稳定的骨折模式,其中十(56%)已收到PCCD。 PCCD正确置于四个(15%)病例中,可接受12(46%),十(39%)不正确。在RR处理的骨盆骨折(n = 77,100%)的所有患者中,只有三分之一(n = 26,34%)具有PCCD。此外,39%的PCCD不正确地定位。在不稳定的骨盆骨折(n = 18,100%)的患者中,超过一半未接受任何PCCD(n = 8,44%),或者具有较不充分定位的(n = 2,11%)。这些结果强调了对PCCD指示和申请的临床技术和临床教育计划应严重重新评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号