首页> 美国卫生研究院文献>Biomedical Reports >Predictive value of combining the level of fibrinogen and antithrombin III for contrast-induced nephropathy in coronary artery disease patients undergoing percutaneous coronary intervention
【2h】

Predictive value of combining the level of fibrinogen and antithrombin III for contrast-induced nephropathy in coronary artery disease patients undergoing percutaneous coronary intervention

机译:结合纤维蛋白原和抗抗凝血酶III水平对冠状动脉疾病患者进行经皮冠状动脉介入的肾病患者的预测值

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Contrast-induced nephropathy (CIN) is a common adverse event in the diagnosis and treatment of coronary intervention. The current study investigated the predictive effect of preoperative fibrinogen (FIB) combined with antithrombin III (AT-III) on CIN following percutaneous coronary intervention (PCI). A total of 394 patients who underwent PCI between October 2018 and May 2019 were selected for the present study. Pre-procedural FIB levels and AT-III activity were measured before PCI. CIN was defined as a 0.5 mg/dl or 25% increase in serum creatinine levels 48 to 72 h after exposure to a radiocontrast agent. Patients were classified into CIN and non-CIN groups. CIN occurred in 48 (12.2%) patients. The serum FIB levels were significantly higher in patients who developed CIN compared with those who did not develop CIN. In addition, AT-III levels ≤89.5% were associated with higher rates of CIN. Logistical regression analysis showed that high FIB, and low AT-III and albumin levels were high-risk factors associated with CIN. For FIB, the area under the receiver operating characteristic curve (AUC) for predicting CIN was 0.653. The optimal cut-off value was 3.48 g/l with a sensitivity of 45.8% and a specificity of 79.7% [95% confidence interval (CI): 0.603-0.701; P=0.0002)]. For AT-III, the AUC was 0.711, and the optimal cut-off value was 89.5%, with a sensitivity of 81.3% and specificity of 58.2% (95% CI: 0.659-0.758; P<0.0001). When combining FIB and AT-III, the AUC was 0.747. The optimal cut-off value was 0.090424, with a diagnostic sensitivity of 93.8% and specificity of 46.6% (95% CI: 0.697-0.792; P<0.0001). The results showed that FIB combined with AT-III resulted in improved predictive accuracy of CIN (FIB vs. AT-III, AUC=0.653 vs. 0.711, P=0.292; FIB vs. FIB + AT-III, AUC=0.653 vs. 0.747, P=0.012; AT-III vs. FIB + AT-III, AUC=0.711 vs. 0.747, P=0.138). Pre-procedural levels of FIB, AT-III and albumin were independently associated with an increased risk of CIN. Furthermore, the results suggested that the combination of FIB and AT-III was a better predictor of CIN after PCI.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号