首页> 美国卫生研究院文献>Physiological Reports >Cross‐validation of equations to predict whole‐body sweat sodium concentration from regional measures during exercise
【2h】

Cross‐validation of equations to predict whole‐body sweat sodium concentration from regional measures during exercise

机译:方程式的交叉验证以预测运动过程中区域措施的全身汗液钠浓度

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We have previously published equations to estimate whole‐body (WB) sweat sodium concentration ([Na ]) from regional (REG) measures; however, a cross‐validation is needed to corroborate the applicability of these prediction equations between studies. The purpose of this study was to determine the validity of published equations in predicting WB sweat [Na ] from REG measures when applied to a new data set. Forty‐nine participants (34 men, 15 women; 75 ± 12 kg) cycled for 90 min while WB sweat [Na ] was measured using the washdown technique. REG sweat [Na ] was measured from seven regions using absorbent patches (3M Tegaderm + Pad). Published equations were applied to REG sweat [Na ] to determine predicted WB sweat [Na ]. Bland–Altman analysis of mean bias (raw and predicted minus measured) and 95% limits of agreement (LOA) were used to compare raw (uncorrected) REG sweat [Na ] and predicted WB sweat [Na ] to measured WB sweat [Na ]. Mean bias (±95% LOA) between raw REG sweat [Na ] and measured WB sweat [Na ] was 10(±20), 0(±19), 9(±20), 22(±25), 23(±24), 0(±15), −4(±18) mmol/L for the dorsal forearm, ventral forearm, upper arm, chest, upper back, thigh, and calf, respectively. The mean bias (±95% LOA) between predicted WB sweat [Na ] and measured WB sweat [Na ] was 3(±14), 4(±12), 0(±14), 2(±17), −2(±16), 5(±13), 4(±15) mmol/L for the dorsal forearm, ventral forearm, upper arm, chest, upper back, thigh, and calf, respectively. Prediction equations improve the accuracy of estimating WB sweat [Na ] from REG and are therefore recommended for use when determining individualized sweat electrolyte losses.
机译:我们之前出版的方程来估计来自区域(reg)措施的全身(WB)汗液浓度([Na]);然而,需要交叉验证来证实研究之间这些预测方程的适用性。本研究的目的是确定当应用于新数据集时从REG措施预测WB汗液[NA]的公开方程的有效性。四十九名参与者(34名男性,15名女性; 75±12千克)循环90分钟,同时使用冲洗技术测量WB汗液[NA]。使用吸收贴剂(3M Tegaderm +垫)从七个区域测量Reg Sweat [Na]。已发表的方程被施用给Reg Sweat [Na]以确定预测的WB汗液[NA]。平均偏差的平坦altman分析(原始和预测减去测量)和95%的协议限制(LOA)用于比较原料(未校正的)reg汗液[na]并预测Wb汗液[na]测量的wb汗液[na] 。原料毒液汗液[Na]之间的平均偏差(±95%LOA)和测量的WB汗液[Na]为10(±20),0(±19),9(±20),22(±25),23(±) 24),0(±15),-4(±18)Mmol / L用于背前臂,腹前臂,上臂,胸部,上背部,大腿和小腿。预测的Wb汗液[Na]和测量的Wb汗液[Na]之间的平均偏置(±95%LOA)为3(±14),4(±12),0(±14),2(±17),-2 (±16),5(±13),4(±15)mmol / L用于背臂前臂,腹前臂,上臂,胸部,上背部,大腿和小牛。预测方程提高了估计来自reg的Wb汗液[Na]的准确性,因此建议在确定个体化汗液电解质损失时使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号