Particulate Production and Composite Dust during Routine Dental Procedures. A Systematic Review with Meta-Analyses

机译:常规牙科程序中的颗粒物产生和复合粉尘。荟萃分析的系统评价

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Composite dust generation is most likely a continuous and daily procedure in dental practice settings. The aim of this systematic review was to identify, compile and evaluate existing evidence on interventions and composite material properties related to the production of aerosolized dust during routine dental procedures. Seven electronic databases were searched, with no limits, supplemented by a manual search, on 27 April 2020 for published and unpublished research. Eligibility criteria comprised of studies of any design, describing composite dust production related to the implementation of any procedure in dental practice. Study selection, data extraction and risk of bias (RoB) assessment was undertaken independently either in duplicate, or confirmed by a second reviewer. Random effects meta-analyses of standardized mean differences (SMD) with associated 95% confidence intervals (CIs) were employed where applicable. A total of 375 articles were initially identified, resulting in 13 articles being included in the qualitative synthesis, of which 5 contributed to meta-analyses overall. Risk of bias recordings ranged between low and high, pertaining to unclear/raising some concerns, in most cases. All types of composites, irrespective of the filler particles, released significant amounts of nano-sized particles after being ground, with potentially disruptive respiratory effects. Evidence supported increased % distribution of particles < 100 nm for nanocomposite Filtek Supreme XTE compared to both conventional hybrid Z100MP (SMD: 1.96, 95% CI: 0.85, 3.07; -value; 0.001) and nano- hybrid Tetric EvoCeram (SMD: 1.62, 95% CI: 0.56, 2.68; -value: 0.003). For cytotoxicity considerations of generated aerosolized particles, both nanocomposites Filtek Supreme XTE and nanohybrid GradiO revealed negative effects on bronchial epithelial cell viability, as represented by % formazan reduction at 330–400 μg/mL for 24 hours, with no recorded differences between them (SMD: 0.19; 95% CI: −0.17, 0.55; -value: 0.30). Effective and more rigorous management of dental procedures potentially liable to the generation of considerable amounts of aerosolized composite dust should be prioritized in contemporary dental practice. In essence, protective measures for the clinician and the practices’ personnel should also be systematically promoted and additional interventions may be considered in view of the existing evidence.
机译:在牙科诊所中,复合粉尘的产生很可能是连续和日常的过程。该系统评价的目的是确定,汇编和评估与常规牙科程序中与产生雾化粉尘有关的干预措施和复合材料特性的现有证据。 2020年4月27日,无限制地搜索了七个电子数据库,并通过人工搜索进行了补充,以进行已发表和未发表的研究。资格标准包括对任何设计的研究,描述与牙科实践中任何程序的实施有关的复合粉尘产生。研究选择,数据提取和偏倚风险(RoB)评估独立进行,一式两份,或由第二位审核者确认。在适用的情况下,使用带有相关95%置信区间(CI)的标准均数差(SMD)的随机效应荟萃分析。最初总共鉴定了375篇文章,导致13篇文章被定性合成,其中5篇对总体分析做出了贡献。在大多数情况下,与不清晰/引起某些担忧有关,偏向记录的风险介于低和高之间。所有类型的复合材料,无论填料颗粒如何,在研磨后都会释放出大量的纳米级颗粒,可能会破坏呼吸。与常规混合Z100MP(SMD:1.96,95%CI:0.85,3.07; -value; 0.001)和纳米混合Tetric EvoCeram(SMD:1.62, 95%CI:0.56,2.68;-值:0.003)。考虑到生成的雾化颗粒的细胞毒性,纳米复合物Filtek Supreme XTE和nanohybrid GradiO均显示出对支气管上皮细胞活力的负面影响,以330-400μg/ mL的甲for减少百分数表示24小时,两者之间没有记录的差异(SMD :0.19; 95%CI:-0.17,0.55;-值:0.30)。在当代牙科实践中,应该优先考虑对牙科程序进行有效且更严格的管理,这可能会导致产生大量的雾化复合粉尘。从本质上讲,还应该系统地促进对临床医生和医务人员的保护措施,并根据现有证据考虑采取其他干预措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号