首页> 美国卫生研究院文献>International Journal of Environmental Research and Public Health >Post-Exercise Recovery of Ultra-Short-Term Heart Rate Variability after Yo-Yo Intermittent Recovery Test and Repeated Sprint Ability Test
【2h】

Post-Exercise Recovery of Ultra-Short-Term Heart Rate Variability after Yo-Yo Intermittent Recovery Test and Repeated Sprint Ability Test

机译:悠悠球间歇性恢复测试和重复冲刺能力测试后运动后恢复超短期心率变异性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study aimed to examine the agreement and acceptance of ultra-short-term heart rate (HR) variability (HRV ) measures during post-exercise recovery in college football players. Twenty-five male college football players (age: 19.80 ± 1.08 years) from the first division of national university championship voluntarily participated in the study. The participants completed both a repeated sprint ability test (RSA) and a Yo-Yo intermittent recovery test level 1 (YYIR1) in a randomized order and separated by 7 days. Electrocardiographic signals (ECG) were recorded in a supine position 10 min before and 30 min after the exercise protocols. The HR and HRV data were analyzed in the time segments of baseline 5~10 min (Baseline), post-exercise 0~5 min (Post 1), post-exercise 5~10 min (Post 2), and post-exercise 25~30 min (Post 3). The natural logarithm of the standard deviation of normal-to-normal intervals (LnSDNN), root mean square of successive normal-to-normal interval differences (LnRMSSD), and LnSDNN:LnRMSSD ratio was compared in the 1st min HRV and 5-min criterion (HRV ) of each time segment. The correlation of time-domain HRV variables to 5-min natural logarithm of low frequency power (LnLF) and high frequency power (LnHF), and LF:HF ratio were calculated. The results showed that the HRV of LnSDNN, LnRMSSD, and LnSDNN:LnRMSSD ratio showed trivial to small effect sizes (ES) (−0.00~0.49), very large and nearly perfect interclass correlation coefficients (ICC) (0.74~0.95), and relatively small values of bias (RSA: 0.01~−0.12; YYIR1: −0.01~−0.16) to the HRV in both exercise protocols. In addition, the HRV of LnLF, LnHF, and LnLF:LnHF showed trivial to small ES (−0.04~−0.54), small to large ICC (−0.02~0.68), and relatively small values of bias (RSA: −0.02~0.65; YYIR1: 0.03~−0.23) to the HRV in both exercise protocols. Lastly, the 1-min LnSDNN:LnRMSSD ratio was significantly correlated to the 5-min LnLF:LnHF ratio with moderate~high level ( = 0.43~0.72; < 0.05) during 30-min post-exercise recovery. The post-exercise 1-min HRV assessment in LnSDNN, LnRMSSD, and LnSDNN:LnRMSSD ratio was acceptable and accurate in the RSA and YYIR1 tests, compared to the 5-min time segment of measurement. The moderate to high correlation coefficient of the HRV LnSDNN:LnRMSSD ratio to the HRV LnLF:LnHF ratio indicated the capacity to facilitate the post-exercise shortening duration of HRV measurement after maximal anaerobic or aerobic shuttle running. Using ultra-short-term record of LnSDNN:LnRMSSD ratio as a surrogate for standard measure of LnLF:LnHF ratio after short-term bouts of maximal intensity field-based shuttle running is warranted.
机译:这项研究旨在检查大学橄榄球运动员运动后恢复过程中超短期心率(HR)变异(HRV)措施的一致性和接受性。全国大学冠军赛第一名的25名男性大学橄榄球运动员(年龄:19.80±1.08岁)自愿参加了这项研究。参与者以随机顺序完成了重复冲刺能力测试(RSA)和悠悠球间歇恢复测试等级1(YYIR1),相隔7天。心电图信号(ECG)记录在运动方案开始前10分钟和运动后30分钟的仰卧位置。在基线5〜10分钟(基准),运动后0〜5分钟(后1),运动后5〜10分钟(后2)和运动后25的时间段内分析HR和HRV数据〜30分钟(发布3)。在第1分钟HRV和第5分钟内比较了正常至正常间隔标准差(LnSDNN),连续的正常至正常间隔差的均方根(LnRMSSD)和LnSDNN:LnRMSSD之比的自然对数每个时间段的标准(HRV)。计算了时域HRV变量与低频功率(LnLF)和高频功率(LnHF)的5分钟自然对数的相关性,以及LF:HF比。结果显示LnSDNN,LnRMSSD和LnSDNN:LnRMSSD之比的HRV显示出微不足道的影响值(ES)(-0.00〜0.49),非常大和接近完美的类间相关系数(ICC)(0.74〜0.95),以及在两种运动方案中,相对于HRV的偏倚值相对较小(RSA:0.01〜-0.12; YYIR1:-0.01〜-0.16)。此外,LnLF,LnHF和LnLF:LnHF的HRV显示从小到小的ES(-0.04〜-0.54),从小到大的ICC(-0.02〜0.68)和相对较小的偏差值(RSA:-0.02〜在两种锻炼方案中,HRV均应为0.65; YYIR1:0.03〜-0.23)。最后,在运动后30分钟恢复过程中,1分钟LnSDNN:LnRMSSD比值与5分钟LnLF:LnHF比值显着相关(中等至高水平(= 0.43〜0.72; <0.05))。与5分钟的测量时间段相比,LnSDNN,LnRMSSD和LnSDNN:LnRMSSD之比的运动后1分钟HRV评估在RSA和YYIR1测试中是可接受且准确的。 HRV LnSDNN:LnRMSSD比值与HRV LnLF:LnHF比值之间的中度到高相关系数表明,在最大厌氧或有氧穿梭运动后,有能力促进HRV测量的运动后缩短持续时间。使用LnSDNN:LnRMSSD比值的超短期记录作为对LnLF:LnHF比值的标准测量的替代,以确保在基于最大强度场的航天飞机运行后进行短期回合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号