摘要

Systematic (Σ) and random (σ) target localization errors of the patient group and related dose-probability-based PTV margins calculated for the MidV approach. Baseline error refers to the residual localization error of the mean time-weighted target position. Iso error refers to the error related to the nonperfect coincidence between imaging and treatment isocenters. MidV error refers to the residual error of localizing the mean time-weighted target position in the MidV CT dataset
机译:患者组的系统(Σ)和随机(σ)目标定位误差以及为MidV方法计算的基于剂量概率的相关PTV幅度。基线误差是指平均时间加权目标位置的残留定位误差。等差误差是指与成像和治疗等中心点之间的非完美重合有关的误差。 MidV误差是指在MidV CT数据集中定位平均时间加权目标位置的残留误差