Comparison of the Next-Generation Xpert MRSA/SA BC Assay and the GeneOhm StaphSR Assay to Routine Culture for Identification of Staphylococcus aureus and Methicillin-Resistant S. aureus in Positive-Blood-Culture Broths

机译:下一代Xpert MRSA / SA BC分析和GeneOhm StaphSR分析与常规培养在阳性血培养液中鉴定金黄色葡萄球菌和耐甲氧西林金黄色葡萄球菌的常规培养的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A bloodstream infection with Staphylococcus aureus, including methicillin-resistant S. aureus (MRSA), is a serious condition that carries a high mortality rate and is also associated with significant hospital costs. The rapid and accurate identification and differentiation of methicillin-susceptible S. aureus (MSSA) and MRSA directly from positive blood cultures has demonstrated benefits in both patient outcome and cost-of-care metrics. We compare the next-generation Xpert MRSA/SA BC (Xpert) assay to the GeneOhm StaphSR (GeneOhm) assay for the identification and detection of S. aureus and methicillin resistance in prospectively collected blood culture broths containing Gram-positive cocci. All results were compared to routine bacterial culture as the gold standard. Across 8 collection and test sites, the Xpert assay demonstrated a sensitivity of 99.6% (range, 96.4% to 100%) and a specificity of 99.5% (range, 98.0% to 100%) for identifying S. aureus, as well as a sensitivity of 98.1% (range, 87.5% to 100%) and a specificity of 99.6% (range, 98.3% to 100%) for identifying MRSA. In comparison, the GeneOhm assay demonstrated a sensitivity of 99.2% (range, 95.2% to 100%) and a specificity of 96.5% (range, 89.2% to 100%) for identifying S. aureus, as well as a sensitivity of 94.3% (range, 87.5% to 100%) and a specificity of 97.8% (range, 96.1% to 100%) for identifying MRSA. Five of six cultures falsely reported as negative for MRSA by the GeneOhm assay were correctly identified as positive by the Xpert assay, while one culture falsely reported as negative for MRSA by the Xpert assay was correctly reported as positive by the GeneOhm assay.
机译:包括耐甲氧西林的金黄色葡萄球菌(MRSA)在内的金黄色葡萄球菌的血液感染是一种严重的疾病,其死亡率很高,并且还与可观的医院费用相关。直接从阳性血液培养物中快速,准确地鉴定和区分对甲氧西林敏感的金黄色葡萄球菌(MSSA)和MRSA,已显示出对患者预后和护理成本指标的益处。我们将下一代Xpert MRSA / SA BC(Xpert)分析与GeneOhm StaphSR(GeneOhm)分析进行比较,以鉴定和检测前瞻性收集的含有革兰氏阳性球菌的血液培养液中的金黄色葡萄球菌和甲氧西林耐药性。将所有结果与常规细菌培养作为金标准进行比较。在8个收集和测试位点中,Xpert分析显示出用于鉴定金黄色葡萄球菌的敏感性为99.6%(范围为96.4%至100%),特异性为99.5%(范围为98.0%至100%)。鉴定MRSA的敏感性为98.1%(范围为87.5%至100%),特异性为99.6%(范围为98.3%至100%)。相比之下,GeneOhm分析显示鉴定金黄色葡萄球菌的灵敏度为99.2%(范围为95.2%至100%),特异性为96.5%(范围为89.2%至100%),灵敏度为94.3% (范围87.5%至100%)和97.8%(范围96.1%至100%)的特异性用于鉴定MRSA。通过Xpert测定法正确鉴定出GeneOhm测定法错误报告为MRSA阴性的6种培养物中的5种,而通过GeneOhm测定法正确鉴定为通过Xpert测定法错误报告为MRSA阴性的一种培养物。