首页> 美国卫生研究院文献>Heliyon >Evaluation of metal-organic framework NH2-MIL-101(Fe) as an efficient sorbent for dispersive micro-solid phase extraction of phenolic pollutants in environmental water samples
【2h】

Evaluation of metal-organic framework NH2-MIL-101(Fe) as an efficient sorbent for dispersive micro-solid phase extraction of phenolic pollutants in environmental water samples

机译:评价金属有机框架NH2-MIL-101(Fe)作为高效吸附剂以分散微固相萃取环境水样中的酚类污染物

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This work proposes an application of amine-functionalized metal-organic framework (NH -MIL-101(Fe)) as sorbent for dispersive micro-solid phase extraction (D-μSPE) of ten priority phenolic pollutants. The sorbent was simply synthesized under facile condition. The entire D-μSPE process was optimized by studying the effect of experimental parameters affecting the extraction recovery of the target analytes. The final extract was analyzed using high performance liquid chromatography with photodiode array detector. Under the optimum condition, the proposed procedure can be applied for wide linear calibration ranges between 1.25–5000 μg L with the correlation coefficients of greater than 0.9900. The limits of detection (LODs) and limits of quantitation (LOQs) were in the ranges of 0.4–9.5 μg L and 1.25–30 μg L , respectively. The precision evaluated in terms of the relative standard deviations (RSDs) of the intra- and inter-day determinations of the phenol compounds at their LOQ concentrations were below 13.9% and 12.2%, respectively. High enrichment factors up to 120 were reached. The developed method has been successfully applied to determine phenol residues in environmental water samples. The satisfactory recoveries obtained by spiking phenol standards at two different concentrations (near LOQs and 5 times as high as LOQs) ranged from 68.4–114.4%. The results demonstrate that the NH -MIL-101(Fe) material is promising sorbent in the D-μSPE of phenolic pollutants.
机译:这项工作提出了胺功能化金属有机骨架(NH -MIL-101(Fe))作为吸附剂的应用,该吸附剂可用于十种优先酚类污染物的分散微固相萃取(D-μSPE)。吸附剂是在容易的条件下简单地合成的。通过研究影响目标分析物提取回收率的实验参数的影响,优化了整个D-μSPE过程。使用具有光电二极管阵列检测器的高效液相色谱法分析最终提取物。在最佳条件下,建议的方法可用于1.25–5000μgL的宽线性校准范围,相关系数大于0.9900。检测限(LOD)和定量限(LOQ)分别在0.4–9.5μgL和1.25–30μgL的范围内。以当日和日间测定酚类化合物在LOQ浓度下的相对标准偏差(RSD)来评估的精密度分别低于13.9%和12.2%。达到了120的高富集因子。该方法已成功应用于环境水样中苯酚残留的测定。通过在两种不同浓度(接近最低定量限和最高定量限的5倍)处加标苯酚标准品,可获得令人满意的回收率,范围为68.4-114.4%。结果表明,NH -MIL-101(Fe)材料在酚类污染物的D-μSPE中具有广阔的前景。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号