Two methods of inoculum preparation for filamentous fungi were compared: counting with a hematocytometer and spectrophotometric adjustment. One hundred eighty-two filamentous fungi pathogenic for humans were used. Colony counts were done for all inoculum preparations. The agreement between the hematocytometer counts and the colony counts (CFU per milliliter) was 97.2%. The reproducibility between the hematocytometer counts and the colony counts by means of an intraclass correlation coefficient was 0.70. Pearson's correlation index for hematocytometer counts versus colony counts was 0.56, whereas that for optical density versus colony counts was 0.008. Both methods can be used for inoculum size adjustment. However, the use of the spectrophotometric method requires that each species be standardized separately.
机译:比较了两种制备丝状真菌接种物的方法:用血细胞计数器计数和分光光度法调整。使用了对人类致病的一百八十二条丝状真菌。对所有接种物进行菌落计数。血细胞计数与菌落计数(每毫升CFU)之间的一致性为97.2%。血细胞计数和菌落计数之间的可重复性通过类内相关系数为0.70。皮尔森血细胞计数与菌落计数的相关指数为0.56,而光密度与菌落计数的相关指数为0.008。两种方法均可用于接种量的调整。但是,使用分光光度法需要对每种物质分别进行标准化。