首页> 美国卫生研究院文献>Journal of Clinical Microbiology >SimulFluor Respiratory Screen for Rapid Detection of Multiple Respiratory Viruses in Clinical Specimens by Immunofluorescence Staining
【2h】

SimulFluor Respiratory Screen for Rapid Detection of Multiple Respiratory Viruses in Clinical Specimens by Immunofluorescence Staining

机译:SimulFluor呼吸屏用于通过免疫荧光染色快速检测临床样本中的多种呼吸道病毒

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A new rapid direct immunofluorescence assay (DFA) respiratory screen reagent for detection of seven common respiratory viruses (respiratory syncytial virus [RSV], influenza A and B viruses, parainfluenza virus types 1 to 3, and adenovirus) was compared with standard single or dual DFA reagents and culture. In total, 1,531 respiratory samples were adequate for testing with both SimulFluor Respiratory Screen (RS) reagent (Chemicon International, Temecula, Calif.) and single or dual DFA reagents. The RS DFA reagent detected 367 (98.4%) and single or dual DFA reagents detected 368 (98.7%) of 373 DFA-positive samples. In addition, the RS DFA reagent was equivalent to or better than culture for detection of all viruses except adenovirus. Only 15 of 799 (1.9%) RS-negative samples inoculated into cell cultures yielded respiratory virus isolates (one RSV, five influenza A virus, two influenza B virus, one parainfluenza virus, and six adenovirus). Sixty-six other virus isolates (13 rhinovirus, 24 cytomegalovirus, 28 herpes simplex virus type 1, and 1 enterovirus) were also recovered in culture. With cytospin preparation of slides, only 7.5% of samples submitted were deemed inadequate for DFA. The availability of a rapid DFA screening reagent for detection of multiple common respiratory viruses within 1 to 2 h of sample collection should be of great benefit in terms of patient management and infection control.
机译:将一种用于检测七种常见呼吸道病毒(呼吸道合胞病毒[RSV],A和B型流感病毒,1至3型副流感病毒和腺病毒)的新型快速直接免疫荧光测定(DFA)呼吸道筛查试剂与标准的单株或双株病毒进行了比较DFA试剂和培养。总共有1,531个呼吸道样品足以用于同时使用SimulFluor呼吸筛查(RS)试剂(Chemicon International,Temecula,加利福尼亚)和单或双DFA试剂。在373个DFA阳性样品中,RS DFA试剂检测到367个(98.4%),单个或双重DFA试剂检测到368个(98.7%)。此外,RS DFA试剂对于检测除腺病毒以外的所有病毒均等同于或优于培养物。接种到细胞培养物中的799株RS阴性样品中,只有15株得到呼吸道病毒分离株(1株RSV,5株A型流感病毒,2株B型流感病毒,1株副流感病毒和6株腺病毒)。在培养物中还回收了66种其他病毒分离株(13种鼻病毒,24种巨细胞病毒,28种单纯疱疹病毒1型和1种肠病毒)。使用cytospin制备载玻片时,只有7.5%提交的样品被认为不足以DFA。就患者管理和感染控制而言,快速DFA筛查试剂可在样品采集后1-2小时内检测多种常见呼吸道病毒应具有极大的优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号