首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Serodiagnosis of Helicobacter pylori infection: comparison and correlation between enzyme-linked immunosorbent assay and rapid serological test results.
【2h】

Serodiagnosis of Helicobacter pylori infection: comparison and correlation between enzyme-linked immunosorbent assay and rapid serological test results.

机译:幽门螺杆菌感染的血清诊断:酶联免疫吸附测定与快速血清学检测结果的比较和相关性。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

CLOser is a new, one-step, qualitative anti-Helicobacter pylori immunoglobulin G test having the advantage of convenience and simplicity. We aimed to evaluate its diagnostic accuracy and to compare it with a quantitative enzyme-linked immunosorbent assay (ELISA) (HEL-pTEST II) in a study of 86 adult dyspeptic patients by using the results from histology and urease testing of gastric biopsies as a "gold standard." Forty-six patients were H. pylori positive. The sensitivities, specificities, and positive and negative predictive values were 95.7, 72.5, 80.0, and 93.5%, respectively, for CLOser and 93.5, 92.5, 93.5, and 92.5%, respectively, for HEL-pTEST II. The grade of the colored test bands in CLOser was correlated with antibody titers in HEL-pTEST II (r = 0.71; p < 0.001). The mean antibody titers were 13, 74, 186, and 328 U/ml for the negative, faint, thin, and thick bands, respectively, of CLOser. We concluded that the CLOser rapid serological test yielded sensitivity similar to that of the conventional ELISA. Although CLOser is not suitable for epidemiologic screening for H. pylori infection on account of lower specificity, it is particularly convenient and very easy to perform. Therefore, it may eventually become widely used in the office-based care of patients and lead to more cost-effective patient management decisions.
机译:CLOser是一种新型的一步式定性抗幽门螺杆菌免疫球蛋白G测试,具有便利和简单的优势。我们的目的是评估其诊断准确性,并将其与定量酶联免疫吸附测定(ELISA)(HEL-pTEST II)进行比较,以86例成年消化不良患者的研究结果为基础,将组织活检结果和胃活检的尿素酶检测结果作为参考。 “黄金标准。” 46例患者幽门螺杆菌阳性。 CLOser的敏感性,特异性以及阳性和阴性预测值分别为95.7、72.5、80.0和93.5%,HEL-pTEST II分别为93.5、92.5、93.5和92.5%。 CLOser中有色测试条的等级与HEL-pTEST II中的抗体滴度相关(r = 0.71; p <0.001)。 CLOser的阴性,微弱,细和粗条带的平均抗体滴度分别为13、74、186和328 U / ml。我们得出的结论是,CLOser快速血清学检测所产生的敏感性与常规ELISA相似。尽管由于特异性较低,CLOser不适合用于幽门螺杆菌感染的流行病学筛查,但它特别方便且非常易于执行。因此,它最终可能会在基于办公室的患者护理中得到广泛使用,并导致更具成本效益的患者管理决策。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号