首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Multicenter evaluation of new double-antigen sandwich enzyme immunoassay for measurement of anti-human immunodeficiency virus type 1 and type 2 antibodies.
【2h】

Multicenter evaluation of new double-antigen sandwich enzyme immunoassay for measurement of anti-human immunodeficiency virus type 1 and type 2 antibodies.

机译:用于测量抗人免疫缺陷病毒1型和2型抗体的新型双抗原夹心酶免疫测定法的多中心评估。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A new enzyme immunoassay (EIA), the Cobas Core Anti-HIV-1/HIV-2 EIA DAGS (also referred to as Roche DAGS), for the detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 was evaluated in four centers. The assay is based on the double-antigen sandwich (DAGS) format, which enables the detection of all classes of antibodies. The antigens consist of recombinant proteins in their native conformation and of synthetic peptides. Of a total of 5,836 negative serum samples, including 95 samples likely to produce false reactivities, 6 were false positive, resulting in a specificity of 99.9%. None of 35 sera that were from noninfected individuals but contained p24-cross-reacting antibodies as revealed by Western blot (immunoblot) analysis were reactive by the Roche DAGS assay. In samples from individuals infected with HIV-1 group M (n = 499) and HIV-2 (n = 200), the sensitivity of the assay was 100%. Although containing antigens with sequences from subtype B only, the assay was also able to correctly identify with high optical density/cutoff ratios samples from subjects infected with HIV-1 subtype O (n = 10). In 17 of 19 seroconversion panels tested, the assay detected the presence of HIV-1 antibodies as early as another sandwich EIA. Eight of these panels were also analyzed by an indirect second-generation assay, which detected antibodies 2 to 10 days later than did the DAGS assay under evaluation. The excellent specificity and sensitivity of the new Cobas Core Anti-HIV-1/HIV-2 EIA DAGS are the result of the DAGS format as well as of the native, naturally folded form of the recombinant protein used as the gag antigen.
机译:一种新的酶免疫测定(EIA),即Cobas Core抗HIV-1 / HIV-2 EIA DAGS(也称为Roche DAGS),用于检测针对人类1型免疫缺陷病毒(HIV-1)和HIV-在四个中心评估了2个。该测定基于双抗原夹心(DAGS)格式,可检测所有类型的抗体。抗原由天然构象的重组蛋白和合成肽组成。在总共5836份阴性血清样本中,包括95份可能产生假反应性的样本,其中6份为假阳性,特异性为99.9%。 Western blot(免疫印迹)分析显示,来自未感染个体但包含p24交叉反应抗体的35种血清中,没有一种通过罗氏DAGS测定具有反应性。在感染了HIV-1 M组(n = 499)和HIV-2(n = 200)的个体的样品中,该测定的灵敏度为100%。尽管仅包含具有来自亚型B的序列的抗原,但该测定法还能够以高光密度/截留比正确鉴定来自感染了HIV-1亚型O(n = 10)的受试者的样品。在测试的19个血清转换小组中,有17个小组早在另一个三明治EIA时就检测到HIV-1抗体的存在。还通过间接第二代测定法分析了这些样本中的八个,该第二代测定法比所评估的DAGS测定法晚2至10天检测到抗体。新型Cobas Core抗HIV-1 / HIV-2 EIA DAGS的优异特异性和敏感性是DAGS格式以及用作gag抗原的重组蛋白的天然,天然折叠形式的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号