首页> 美国卫生研究院文献>Journal of Digital Imaging >Orthodontic Study Cast Analysis—Reproducibility of Recordings and Agreement Between Conventional and 3D Virtual Measurements
【2h】

Orthodontic Study Cast Analysis—Reproducibility of Recordings and Agreement Between Conventional and 3D Virtual Measurements

机译:正畸研究模型分析-记录的可再现性以及常规和3D虚拟测量之间的一致性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Digital imaging of dental casts has become an alternative to conventional cast analysis in orthodontic treatment planning. The reproducibility of angular measurements made on virtual digital models has not as yet been evaluated. In order to study reproducibility for and agreement between a conventional analysis technique and virtual 3D imaging, 20 dental casts from subjects in the early mixed dentition, were measured twice with each technique by two orthodontists. Variables of interest were incisor rotation, angulation and irregularity, arch width, arch circumference, overjet, and overbite. Standard deviation (Dahlberg 1940) and coefficient of variation were used for evaluation of reproducibility. Mean differences between methods and examiners, correlation between mean differences and mean levels and 95% limits of agreement were used for describing systematic errors. The conventional technique showed less intraexaminer variation for angular variables than the 3D imaging method. Linear variables, with the exception of overbite, showed no clear trend as regards differences in reproducibility between the two methods. In general, examiner 1 showed less intraexaminer variation than examiner 2. The mean differences between the two methods expressed higher values for assessment of rotations with the O3DM method. Both angular and linear variables exhibited poor 95% limits of agreement. The conventional technique showed better overall reproducibility and thus appears to be more suitable for scientific work. However, the reproducibility attained by O3DM is clearly acceptable for clinical use. The two methods should not be used interchangeably.
机译:牙齿铸模的数字成像已成为正畸治疗计划中常规铸模分析的替代方法。尚未评估在虚拟数字模型上进行的角度测量的可重复性。为了研究常规分析技术和虚拟3D成像的可重复性和一致性,由两名牙齿矫正医生使用每种技术对来自早期混合牙列的20个牙模进行了两次测量。感兴趣的变量是门牙旋转,成角度和不规则度,牙弓宽度,牙弓周长,过喷射和咬合。使用标准偏差(Dahlberg 1940)和变异系数评估可重复性。方法和检查者之间的均值差异,均值差异与均值水平之间的相关性以及95%的一致限用于描述系统误差。与3D成像方法相比,传统技术对角度变量显示的检查者内部变化较小。关于重覆性,线性变量在两种方法之间的可重复性方面没有明显的趋势。通常,检查者1的内部检查者变异小于检查者2。两种方法之间的平均差异表示使用O3DM方法评估旋转的更高值。角度和线性变量都显示出差的95%一致性极限。常规技术显示出更好的整体重现性,因此似乎更适合于科学工作。但是,O3DM获得的可重复性对于临床用途显然是可以接受的。两种方法不应互换使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号