首页> 美国卫生研究院文献>other >Evaluation of Up-Converting Phosphor Technology-Based Lateral Flow Strips for Rapid Detection of Bacillus anthracis Spore Brucella spp. and Yersinia pestis
【2h】

Evaluation of Up-Converting Phosphor Technology-Based Lateral Flow Strips for Rapid Detection of Bacillus anthracis Spore Brucella spp. and Yersinia pestis

机译:基于上转换磷光体技术的横向流条用于快速检测炭疽芽孢杆菌孢子布鲁氏菌属和鼠疫耶尔森氏菌的评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Bacillus anthracis, Brucella spp., and Yersinia pestis are zoonotic pathogens and biowarfare- or bioterrorism-associated agents that must be detected rapidly on-site from various samples (e.g., viscera and powders). An up-converting phosphor technology-based lateral flow (UPT–LF) strip was developed as a point-of-care testing (POCT) to satisfy the requirements of first-level emergency response. We developed UPT–LF POCT to quantitatively detect the three pathogens within 15 min. Sample and operation-error tolerances of the assay were comprehensively evaluated. The sensitivity of UPT–LF assay to bacterial detection reached 104 cfu·mL−1 (100 cfu/test), with a linear quantitative range of 4 to 6 orders of magnitude. Results revealed that the UPT–LF assay exhibited a high specificity with the absence of false-positive results even at 109 cfu·mL−1 of non-specific bacterial contamination. The assay could tolerate samples with a wide pH range (2 to 12), high ion strengths (≥4 mol·L−1 of NaCl), high viscosities (≤25 mg·mL−1 of or ≥20% of glycerol), and high concentrations of bio-macromolecule (≤200 mg·mL−1 of bovine serum albumin or ≥80 mg·mL−1 of casein). The influence of various types of powders and viscera (fresh and decomposed) on the performance of UPT–LF assay was determined. The operational error of liquid measurement exhibited few effects on sensitivity and specificity. The developed UPT–LF POCT assay is applicable under field conditions with excellent tolerance to sample complexity and operational error.
机译:炭疽芽孢杆菌,布鲁氏菌属和鼠疫耶尔森菌是人畜共患病原体以及与生物战或生物恐怖主义有关的病原,必须从各种样品(例如内脏和粉末)中迅速对其进行检测。开发了一种基于上转换荧光粉技术的侧向流动(UPT–LF)带材作为即时检验(POCT),以满足一级紧急响应的要求。我们开发了UPT–LF POCT以在15分钟内定量检测三种病原体。全面评估了样品的耐受性和操作误差。 UPT–LF分析对细菌检测的敏感性达到10 4 cfu·mL -1 (100 cfu /测试),线性定量范围为4至6个数量级大小。结果表明,即使在10 9 cfu·mL -1 非特异性细菌污染的情况下,UPT-LF检测法仍具有很高的特异性,并且没有假阳性结果。该测定法可耐受宽pH范围(2至12),高离子强度(NaCl≥4mol·L -1 ),高粘度(≤25mg·mL -)的样品1 或≥20%的甘油)和高浓度的生物大分子(≤200 mg·mL -1 牛血清白蛋白或≥80 mg·mL − 1 酪蛋白)。确定了各种类型的粉末和内脏(新鲜和分解的)对UPT-LF测定性能的影响。液体测量的操作误差对灵敏度和特异性几乎没有影响。研发的UPT–LF POCT测定法可在野外条件下使用,对样品复杂性和操作误差具有极好的耐受性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号