Correlation of Respirator Fit Measured on Human Subjects and a Static Advanced Headform

机译:在人体上测量的呼吸器适合度与静态高级头戴式耳机的相关性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study assessed the correlation of N95 filtering face-piece respirator (FFR) fit between a Static Advanced Headform (StAH) and 10 human test subjects. Quantitative fit evaluations were performed on test subjects who made three visits to the laboratory. On each visit, one fit evaluation was performed on eight different FFRs of various model/size variations. Additionally, subject breathing patterns were recorded. Each fit evaluation comprised three two-minute exercises: “Normal Breathing,” “Deep Breathing,” and again “Normal Breathing.” The overall test fit factors (FF) for human tests were recorded. The same respirator samples were later mounted on the StAH and the overall test manikin fit factors (MFF) were assessed utilizing the recorded human breathing patterns. Linear regression was performed on the mean log10-transformed FF and MFF values to assess the relationship between the values obtained from humans and the StAH.This is the first study to report a positive correlation of respirator fit between a headform and test subjects. The linear regression by respirator resulted in R2 = 0.95, indicating a strong linear correlation between FF and MFF. For all respirators the geometric mean (GM) FF values were consistently higher than those of the GM MFF. For 50% of respirators, GM FF and GM MFF values were significantly different between humans and the StAH. For data grouped by subject/respirator combinations, the linear regression resulted in R2 = 0.49. A weaker correlation (R2 = 0.11) was found using only data paired by subject/respirator combination where both the test subject and StAH had passed a real-time leak check before performing the fit evaluation. For six respirators, the difference in passing rates between the StAH and humans was < 20%, while two respirators showed a difference of 29% and 43%. For data by test subject, GM FF and GM MFF values were significantly different for 40% of the subjects. Overall, the advanced headform system has potential for assessing fit for some N95 FFR model/sizes.
机译:这项研究评估了N95过滤式面罩呼吸器(FFR)配合在静态高级头罩(StAH)与10位人体测试受试者之间的相关性。进行了三次访问实验室的测试对象进行了定量拟合评估。每次拜访时,都会对各种型号/尺寸变化的八个不同FFR进行一次拟合评估。另外,记录受试者的呼吸模式。每个适合度评估都包括三个两分钟的练习:“正常呼吸”,“深度呼吸”和“正常呼吸”。记录用于人体测试的总体测试拟合因子(FF)。随后将相同的呼吸器样品安装在StAH上,并使用记录的人类呼吸模式评估整体测试人体模型拟合因子(MFF)。对log10转换后的FF和MFF平均值进行线性回归,以评估从人和StAH获得的值之间的关系。这是第一项报道头戴式呼吸机与测试对象之间呼吸器适合度呈正相关的研究。呼吸器的线性回归结果为R 2 = 0.95,表明FF和MFF之间存在很强的线性相关性。对于所有呼吸器,几何平均值(GM)FF值始终高于GM MFF。对于50%的呼吸器,人与StAH之间的GM FF和GM MFF值显着不同。对于按受试者/呼吸器组合分组的数据,线性回归得出R 2 = 0.49。仅使用受试者/呼吸器组合配对的数据发现相关性较弱(R 2 = 0.11),在该数据中,测试对象和StAH均在执行适合度评估之前均通过了实时泄漏检查。对于六个呼吸器,StAH与人类之间通过率的差异小于20%,而两个呼吸器则显示出29%和43%的差异。对于测试对象的数据,对于40%的对象,GM FF和GM MFF值显着不同。总体而言,先进的头模系统具有评估某些N95 FFR型号/尺寸的合身性的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号