首页> 美国卫生研究院文献>other >Quantitative assessment of rotator cuff muscle elasticity: Reliability and feasibility of shear wave elastography
【2h】

Quantitative assessment of rotator cuff muscle elasticity: Reliability and feasibility of shear wave elastography

机译:肩袖肌弹性的定量评估:剪切波弹性成像的可靠性和可行性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Ultrasound imaging has been used to evaluate various shoulder pathologies, whereas, quantification of the rotator cuff muscle stiffness using shear wave elastography (SWE) has not been verified. The purpose of this study was to investigate the reliability and feasibility of SWE measurements for the quantification of supraspinatus (SSP) muscle elasticity. Thirty cadaveric shoulders (18 intact and 12 with torn rotator cuff) were used. Intra- and inter-observer reliability was evaluated on an established SWE technique for measuring the SSP muscle elasticity. To assess the effect of overlying soft tissues above the SSP muscle, SWE values were measured with the transducer placed on the skin, on the subcutaneous fat after removing the skin, on the trapezius muscle after removing the subcutaneous fat, and directly on the SSP muscle. In addition, SWE measurements on 4 shoulder positions (0°, 30°, 60°, and 90° abduction) were compared in those with/without rotator cuff tears. Intra- and inter-observer reliability of SWE measurements were excellent for all regions in SSP muscle. Also, removing the overlying soft tissue showed no significant difference on SWE values measured in the SSP muscle. The SSP muscle with 0° abduction showed large SWE values, whereas, shoulders with large-massive tear showed smaller variation throughout the adduction-abduction positions. SWE is a reliable and feasible tool for quantitatively assessing the SSP muscle elasticity. This study also presented SWE measurements on the SSP muscle under various shoulder abduction positions which might help characterize patterns in accordance to the size of rotator cuff tears.
机译:超声成像已被用于评估各种肩部病变,而使用剪切波弹性成像(SWE)对肩袖肌僵硬度的量化尚未得到验证。这项研究的目的是调查SWE测量用于量化棘上肌(SSP)肌肉弹性的可靠性和可行性。使用了30个尸体肩膀(完整的18个肩膀和旋转的袖口12个肩膀)。观察者之间和观察者之间的可靠性是通过已建立的用于测量SSP肌肉弹性的SWE技术进行评估的。为了评估上方SSP肌肉上的软组织的影响,通过将传感器放置在皮肤上,去除皮肤后皮下脂肪,去除皮下脂肪后斜方肌以及直接在SSP肌肉上测量SWE值。此外,在有/没有肩袖撕裂的情况下,比较了在四个肩部位置(外展0°,30°,60°和90°)的SWE测量值。在SSP肌肉的所有区域,SWE测量的观察者内和观察者之间的可靠性都非常好。同样,去除上面的软组织对SSP肌肉中测得的SWE值也没有显着差异。外展为0°的SSP肌肉显示较大的SWE值,而大内含撕裂的肩膀在整个内收-外展位置上均显示较小的变化。 SWE是定量评估SSP肌肉弹性的可靠且可行的工具。这项研究还提出了在各种肩关节外展姿势下对SSP肌肉的SWE测量,这可能有助于根据肩袖撕裂的大小来表征图案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号