首页> 美国卫生研究院文献>other >THE RIB CAGE REDUCES INTERVERTEBRAL DISC PRESSURES IN CADAVERIC THORACIC SPINES BY SHARING LOADING UNDER APPLIED DYNAMIC MOMENTS
【2h】

THE RIB CAGE REDUCES INTERVERTEBRAL DISC PRESSURES IN CADAVERIC THORACIC SPINES BY SHARING LOADING UNDER APPLIED DYNAMIC MOMENTS

机译:肋骨笼在施加动态力的作用下共享载荷降低胸椎椎间盘椎间盘压力。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The effects of the rib cage on thoracic spine loading are not well studied, but the rib cage may provide stability or share loads with the spine. Intervertebral disc pressure provides insight into spinal loading, but such measurements are lacking in the thoracic spine. Thus, our objective was to examine thoracic intradiscal pressures under applied pure moments, and to determine the effect of the rib cage on these pressures. Human cadaveric thoracic spine specimens were positioned upright in a testing machine, and Dynamic pure moments (0 to ±5 N·m) with a compressive follower load of 400 N were applied in axial rotation, flexion - extension, and lateral bending. Disc pressures were measured at T4-T5 and T8-T9 using needle-mounted pressure transducers, first with the rib cage intact, and again after the rib cage was removed. Changes in pressure vs. moment slopes with rib cage removal were examined. Pressure generally increased with applied moments, and pressure-moment slope increased with rib cage removal at T4-T5 for axial rotation, extension, and lateral bending, and at T8-T9 for axial rotation. The results suggest the intact rib cage carried about 62% and 56% of axial rotation moments about T4-T5 and T8-T9, respectively, as well as 42% of extension moment and 36–43% of lateral bending moment about T4-T5 only. The rib cage likely plays a larger role in supporting moments than compressive loads, and may also play a larger role in the upper thorax than the lower thorax.
机译:肋骨对胸椎负荷的影响尚未得到很好的研究,但肋骨可提供稳定性或与脊椎分担负荷。椎间盘压力可洞悉脊柱负荷,但胸椎缺乏这种测量。因此,我们的目的是在施加纯力矩的情况下检查胸椎间盘内压力,并确定肋骨保持架对这些压力的影响。将人体尸体胸椎标本垂直放置在测试机中,并在轴向旋转,屈曲-伸展和横向弯曲中施加具有400 N压缩随动载荷的动态纯力矩(0至±5 N·m)。使用针头式压力传感器在T4-T5和T8-T9处测量椎间盘压力,首先保持肋骨保持完整,然后再取下肋骨保持架。检查了压力与力矩斜率随肋骨保持架拆除的变化。压力通常随施加的力矩而增加,而压力矩斜率随T4-T5处的肋骨笼的移除而增加,以进行轴向旋转,延伸和横向弯曲,而在T8-T9处进行轴向旋转。结果表明,完整的肋骨保持架分别承担大约T4-T5和T8-T9的轴向旋转力矩的62%和56%,以及大约T4-T5的42%的延伸力矩和36-43%的侧弯力矩。只要。肋骨保持架在支撑力矩中的作用可能比压缩载荷更大,并且在上胸廓中也可能在下胸廓中起更大的作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号