The NIST Net-Zero Energy Residential Test Facility (NZERTF) is a highly instrumented, highly configurable, single-family, net-zero energy house occupied by a virtual family of four. A detailed transient model of the NZERTF and the accompanying mechanical equipment was created using information available before construction; the model incorporated building geometric details and construction material properties, as well as manufacturers’ specifications for HVAC, water heating, solar PV and other equipment. This model represents the typical design paradigm, where actual building performance and detailed equipment operation are not known. This original model underpredicted the measured annual energy consumption by 13.8 %.The measured data were used to understand and correct the sources of error at the component level; modifications to the HVAC system, interior thermal capacitance, and domestic hot water system improved the energy consumption prediction to within 1.6 % of measured data. The differences between the original and modified models are useful for understanding the sources, magnitudes, and possible corrections to errors in energy models for high-efficiency residences. The modified model will be used in future studies of alternative energy system configurations and control strategies, contributing to cost-effective and optimum design of net-zero energy houses in America.
机译:NIST净零能耗住宅测试设施(NZERTF)是一个高度仪器化,高度可配置的单户净零能耗房屋,由一个虚拟的四口之家占用。 NZERTF及其随附的机械设备的详细瞬态模型是根据施工前可用的信息创建的;该模型结合了建筑的几何细节和建筑材料特性,以及制造商的HVAC,水加热,太阳能PV和其他设备的规格。该模型代表了典型的设计范例,其中实际的建筑物性能和详细的设备操作尚不清楚。这个原始模型低估了测得的年度能源消耗13.8%。测得的数据用于理解和纠正组件级别的错误来源;对HVAC系统,内部热容和生活热水系统的修改将能耗预测提高到测量数据的1.6%以内。原始模型和修改后的模型之间的差异对于理解源,大小以及对高效住宅能源模型中的误差可能进行的校正很有用。修改后的模型将用于替代能源系统配置和控制策略的未来研究中,从而有助于实现美国净零能耗房屋的成本效益和最佳设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号