Computer assisted versus conventional cemented total knee prostheses alignment accuracy and micromotion of the tibial component

机译:计算机辅助与传统胶合全膝关节假体的对准精度和胫骨组件的微动

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We evaluated the influence of CT-free or CT-based computer assisted orthopaedic surgery (CAOS) on the alignment of total knee prostheses (TK) and micromotion of tibial components. This randomised study compared 19 CT-free, 17 CT-based CAOS TK, and a matched control group of 21 conventionally placed TK. Using Roentgen stereophotogrammetric analysis (RSA) the migration was measured. The alignment and component positions were measured on radiographs. No significant difference in leg and tibial component alignment was present between the three groups. A significant difference was found for micromotion in subsidence, with the conventional group having a mean of 0.16 mm, compared to the CT-free group at 0.01 mm and the CT-based group at −0.05 mm. No clinical significant difference in alignment was found between CAOS and conventionally operated TK. More subsidence of the tibial component was seen in the conventional group compared to both CAOS groups at two year follow-up.
机译:我们评估了无CT或基于CT的计算机辅助骨科手术(CAOS)对全膝关节假体(TK)对齐和胫骨组件微动的影响。这项随机研究比较了19例无CT,17例基于CT的CAOS TK,以及与之匹配的对照组的21例常规放置的TK。使用Roentgen立体摄影测量分析(RSA)测量迁移。在射线照相上测量对准和部件位置。三组之间的腿部和胫骨组件对齐没有显着差异。发现沉陷中的微动有显着差异,常规组的平均值为0.16mm,而无CT组的平均值为0.01mm,基于CT的组的平均值为-0.05mm。在CAOS和常规操作的TK之间未发现对齐方面的临床显着差异。在两年的随访中,与两个CAOS组相比,常规组的胫骨成分下沉更多。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号