Dosimetric properties of equivalent‐quality flattening filter‐free (FFF) and flattened photon beams of Versa HD linear accelerator

机译:Versa HD线性加速器的等效质量平坦化无滤波器(FFF)和平坦化光子束的剂量学特性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study presents the basic dosimetric properties of photon beams of a Versa HD linear accelerator (linac), which is capable of delivering flattening filter‐free (FFF) beams with a beam quality equivalent to the corresponding flattened beams based on comprehensive beam data measurement. The analyzed data included the PDDs, profiles, penumbra, out‐of‐field doses, surface doses, output factors, head and phantom scatter factors, and MLC transmissions for both FFF and flattened beams of 6 MV and 10 MV energy from an Elekta Versa HD linac. The 6MVFFF and 10MVFFF beams had an equivalent mean energy to the flattened beams and showed less PDD variations with the field sizes. Compared with their corresponding flattened beams, Dmax was deeper for FFF beams for all field sizes; the ionization ratio variations with the field size were lower for FFF beams; the out‐of‐field doses were lower and the penumbras were sharper for the FFF beams; the off‐axis profile variations with the depths were lesser for the FFF beams. Further, the 6MVFFF and 10MVFFF beams had 35.7% and 40.9% less variations in output factor with the field size, respectively. The collimator exchange effect was reduced in the FFF mode. The head scatter factor showed 59.1% and 73.6% less variations, on average, for the 6MVFFF and 10MVFFF beams, respectively; the variations in the phantom scatter factor were also smaller. The surface doses for all beams increased linearly with the field size. The 6MVFFF and 10MVFFF beams had higher surface doses than the corresponding flattened beams for field sizes of up to 10 × 10cm2 but had lower surface doses for larger fields. Both FFF beams had lower average MLC transmissions than the flattened beams. The finding that the FFF beams were of equivalent quality to the corresponding flattened beams indicates a significant difference from the data on unmatched FFF beams.PACS number(s): 87.56.bd, 87.55.Qr
机译:这项研究介绍了Versa HD线性加速器(直线加速器)的光子束的基本剂量学特性,它能够基于综合束数据测量,提供与相应的展平光束等效的光束质量的展平无滤镜(FFF)光束。分析数据包括Elekta Versa的6 MV和10 MV能量的FFF和扁平光束的PDD,轮廓,半影,场外剂量,表面剂量,输出因子,头部和幻影散射因子以及MLC透射率高清直线加速器。 6MVFFF和10MVFFF光束具有与扁平光束等效的平均能量,并且随场大小显示的PDD变化较小。与相应的扁平光束相比,对于所有尺寸的FFF光束,Dmax都更深。 FFF束的电离率随场大小的变化较小。 FFF光束的场外剂量较低,半影锐利; FFF光束的轴剖面轮廓随深度的变化较小。此外,6MVFFF和10MVFFF光束的输出因数随场大小的变化分别减小了35.7%和40.9%。在FFF模式下,准直器交换效果降低。 6MVFFF和10MVFFF光束的平均头散度变化分别减少了59.1%和73.6%。幻影散射因子的变化也较小。所有光束的表面剂量随场大小线性增加。对于最大尺寸为10×10cm 2 的场,6MVFFF和10MVFFF光束的表面剂量高于相应的扁平光束,但对于较大的场,其表面剂量较低。两条FFF光束的平均MLC透射率均低于平坦光束。 FFF光束与相应的扁平光束具有同等质量的发现表明与未匹配的FFF光束的数据存在显着差异.PACS编号:87.56.bd,87.55.Qr

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号