首页> 美国卫生研究院文献>Oncology Letters >Advantages and disadvantages of F-18 fluorodeoxyglucose positron emission tomography/computed tomography in carcinoma of unknown primary
【2h】

Advantages and disadvantages of F-18 fluorodeoxyglucose positron emission tomography/computed tomography in carcinoma of unknown primary

机译:F-18氟脱氧葡萄糖正电子发射断层扫描/计算机断层扫描在未知原发癌中的优缺点

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Carcinoma of unknown primary is a type of malignant disease where the primary carcinoma cannot be identified by conventional examination, which presents challenges in diagnosis and therapy. This study aims to evaluate the detailed clinical value and indications of using fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in a large sample. A total of 449 patients who were selected under strict standards were retrospectively included in this study. F-18 FDG PET/CT accurately detected the primary carcinoma in 115 of 449 patients whose primaries could not be detected by conventional examination (25.6%), with additional 27 false-positive patients. The most common primary site was the lung (34.8%). In addition, except for in metastatic melanoma (1/19, 5.3%) and axillary metastasis patients (2/49, 4.1%), F-18 FDG PET/CT had a comparative performance in detecting primary carcinoma in other pathological types and anatomical locations. The scan is able to guide treatment strategy modifications to some extent (130/449, 29.0%). We strongly recommend the use of F-18 FDG PET/CT in the early phase of examination. It is also recommended as a supplementary radiological method, and certain patients may benefit from its application in cases where regular examination is inconclusive. However, in metastatic melanoma or axillary metastasis patients where the primary site cannot be identified by routine examination, regular application of F-18 FDG PET/CT for the sole purpose of detecting the primary carcinoma should not be encouraged.
机译:原发性未知癌是一类恶性疾病,通过常规检查无法鉴别出原发癌,这给诊断和治疗带来了挑战。本研究旨在评估在大样本中使用氟-18-2-氟-2-脱氧-D-葡萄糖正电子发射断层扫描/计算机断层扫描(F-18 FDG PET / CT)的详细临床价值和适应症。本研究回顾性纳入了总共449例在严格标准下选择的患者。 F-18 FDG PET / CT可以准确检测出449例患者中的115例原发癌,而常规检查无法检测到原发癌(占25.6%),另外还有27例假阳性患者。最常见的原发部位是肺(34.8%)。此外,除了转移性黑色素瘤(1 / 19,5.3%)和腋窝转移患者(2 / 49,4.1%)外,F-18 FDG PET / CT在检测其他病理类型和解剖学上的原发癌方面具有比较性能。位置。扫描能够在一定程度上指导治疗策略的修改(130 / 449,29.0%)。我们强烈建议在检查的早期使用F-18 FDG PET / CT。还建议将其作为补充放射学方法,某些患者在定期检查尚无定论的情况下可能会受益于该方法。但是,在不能通过常规检查确定主要部位的转移性黑色素瘤或腋窝转移患者中,不应鼓励仅出于检测原发癌的目的而定期应用F-18 FDG PET / CT。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号