Quantification of breast arterial calcification using full field digital mammography

机译:使用全视野数字化乳腺X射线摄影术定量量化乳腺动脉钙化

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Breast arterial calcification is commonly detected on some mammograms. Previous studies indicate that breast arterial calcification is evidence of general atherosclerotic vascular disease and it may be a useful marker of coronary artery disease. It can potentially be a useful tool for assessment of coronary artery disease in women since mammography is widely used as a screening tool for early detection of breast cancer. However, there are currently no available techniques for quantification of calcium mass using mammography. The purpose of this study was to determine whether it is possible to quantify breast arterial calcium mass using standard digital mammography. An anthropomorphic breast phantom along with a vessel calcification phantom was imaged using a full field digital mammography system. Densitometry was used to quantify calcium mass. A calcium calibration measurement was performed at each phantom thickness and beam energy. The known (K) and measured (M) calcium mass on 5 and 9 cm thickness phantoms were related by M=0.964K−0.288 mg (r=0.997 and SEE=0.878 mg) and M=1.004K+0.324 mg (r=0.994 and SEE=1.32 mg), respectively. The results indicate that accurate calcium mass measurements can be made without correction for scatter glare as long as careful calcium calibration is made for each breast thickness. The results also indicate that composition variations and differences of approximately 1 cm between calibration phantom and breast thickness introduce only minimal error in calcium measurement. The uncertainty in magnification is expected to cause up to 5% and 15% error in calcium mass for 5 and 9 cm breast thicknesses, respectively. In conclusion, a densitometry technique for quantification of breast arterial calcium mass was validated using standard full field digital mammography. The results demonstrated the feasibility and potential utility of the densitometry technique for accurate quantification of breast arterial calcium mass using standard digital mammography.
机译:乳房动脉钙化通常在一些乳房X光照片上检测到。先前的研究表明,乳房动脉钙化是一般动脉粥样硬化性血管疾病的证据,并且可能是冠状动脉疾病的有用标志。由于乳房X线照相术被广泛用作乳腺癌的早期检测的筛查工具,因此它可能是评估女性冠状动脉疾病的有用工具。然而,目前尚无利用乳腺X射线摄影术定量钙质的可用技术。这项研究的目的是确定是否可以使用标准的乳腺X线摄影术来量化乳腺动脉钙量。使用全视野数字化乳腺X线摄影系统对拟人化的乳房幻影以及血管钙化幻影进行成像。使用光密度测定法定量钙质量。在每个体模厚度和束能量下进行钙校准测量。在5和9 cm厚的模型上已知的(K)和测得的(M)钙质量与M = 0.964K-0.288 mg(r = 0.997和SEE = 0.878 mg)和M = 1.004K + 0.324 mg(r = 0.994和SEE = 1.32 mg)。结果表明,只要对每个乳房厚度进行仔细的钙校准,就可以进行准确的钙质量测量而无需校正散射眩光。结果还表明,校准体模与乳房厚度之间的成分变化和大约1 cm的差异仅在钙测量中引入了最小的误差。放大倍率的不确定性预期分别导致5厘米和9厘米乳房厚度的钙质误差分别为5%和15%。总之,使用标准的全视野数字化乳腺X线摄影术验证了定量乳腺动脉钙量的光密度测定技术。结果表明,使用标准的数字乳腺X线摄影术,光密度法可以准确定量乳腺动脉钙质,具有可行性和潜在的实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号